Manual
Total
2. Total  the EDM-760 fuel used and  the actual fuel used for each 
tank.
3. Record the current K factor here  left_________ right_________ 
and in the table below.
4. Calculate the New K Factor as follows:
New K Factor = (     EDM-760 fuel used)    x (     Current K factor)   
(actual fuel used)
New K Factor (L) = (     (L)                   )   x (     (L)                       )  
((L) )
New K Factor (R )= (     (R)                       )   x (     (R)                      )  
( (R) )
Every time you fine tune the K factors, record the measurements here:
Date
EDM-
760 fuel  
used
actual  
fuel used
Current K 
factor
Left Right
New K factor
= 
x
/
Left Right
Fuel Flow Option Programming Procedure
Setting the K factor 
This procedure is different than for setting other parameters. Place the 
select switch in the FF position. If you haven’t already done so, start the 
pilot programming procedure, simultaneously hold the STEP and LF 
buttons for five seconds. You will see the word PROGRAM for two 
seconds.
1. Tap STEP button to advance to the screen 29.00=KF
LFT
For Your Safe Flight Page 41