Manual

Total
2. Total the EDM-760 fuel used and the actual fuel used for each
tank.
3. Record the current K factor here left_________ right_________
and in the table below.
4. Calculate the New K Factor as follows:
New K Factor = ( EDM-760 fuel used) x ( Current K factor)
(actual fuel used)
New K Factor (L) = ( (L) ) x ( (L) )
((L) )
New K Factor (R )= ( (R) ) x ( (R) )
( (R) )
Every time you fine tune the K factors, record the measurements here:
Date
EDM-
760 fuel
used
actual
fuel used
Current K
factor
Left Right
New K factor
=
x
/
Left Right
Fuel Flow Option Programming Procedure
Setting the K factor
This procedure is different than for setting other parameters. Place the
select switch in the FF position. If you haven’t already done so, start the
pilot programming procedure, simultaneously hold the STEP and LF
buttons for five seconds. You will see the word PROGRAM for two
seconds.
1. Tap STEP button to advance to the screen 29.00=KF
LFT