Manual
Tap STEP
advances to
next item
Tap the LF
button to
sequence
Comments
TIME 2 500
Record time interval, in seconds
MNTH I I2
Month
DAY I 3I
Day
YEAR 00 99
Year (note: represents 1980 through 2079)
HOUR OO 23
24 hour time. We suggest you set Zulu time
MIN OO 59
This also zeros the seconds
N-----
N
I23456
Displays current Aircraft ID. To change Aircraft
ID, hold both STEP and LF buttons
simultaneously until the first character flashes.
Use LF to select the first character. STEP
moves to the next character. To Save the
Aircraft ID, Hold both STEP and LF for 5 sec.
END Y
Tap STEP button to exit the procedure.
Alarm Limits
Factory Set Default Limits
JPI conservatively sets the default alarm limits below Lycoming and
Continental recommendations.
Measuremen
t
Default Low
Limit
Default High Limit Example
CHT 450°F 230°C
465
CHT
OIL 90°
F
32°C 230°F 110°C
280
OIL
TIT 1650°F 900°C
I720
TIT
CLD -60°F/min. -33°C/min.
-65
CLD
DIF 500°F 280°C
525
DIF
BAT, 24 V 24V 32V
22 .4
BAT
BAT, 12 V 12V 16V
I7.6
BAT
LO FUEL 45 min
00.20
H.M
For Your Safe Flight Page 43