Manual
LO TIME 10 gal, kg, ltr, lbs
7.2 
REM
If you change the display to Celsius, be sure to change the alarm limits to 
Celsius degrees. This is not done for you automatically. When an alarm is 
displayed, tapping the STEP button will temporarily delete that 
measurement from the sequence for the next ten minutes. When an alarm 
is displayed, holding the STEP button until the word OFF appears will 
delete that measurement from the sequence for the remainder of the flight.
Changing the Alarm Limits
You may prefer to set your own alarm limits Follow the procedure 
outlined below to change any of the factory default settings.
To start the alarm limit procedure, after power up, wait until the EDM-
760 completes its self test and is in the Automatic or Manual indexing 
mode. If in doubt, tap the STEP button a few times. Then follow the 
steps depicted here:
Hold both
buttons for 5
seconds until
the words
FAC LIM
Tap STEP
button until
the words
END Y
Hold both
buttons for 5
seconds until
the word
PROGRAM
The display will then sequence as shown in the chart below. Tap the 
STEP button to advance to the next item in the list. Tap the LF button to 
select alternate values of that item. Hold the LF button to increase a 
numerical value; tap the LF button to decrease a numerical value. The 
shaded areas in the chart below pertain to the Fuel Flow Option only.
Page 44 Engine Data Management