Installation Manual User Manual

J.P.Instruments Fuel Flow Installation Manual Report # 400
FS-450 Page 9 of 16
Rev A : Date 02/1/2002
10 Specifications and Limitations
Instrument P/N 450000-P, -D
Transducer P/N, 700900-1
Instrument P/N 450000-G
Transducer P/N 700900-2
Range: 0.6 to 60 GPH Range: 3 to 90 GPH
Linearity: %1 (8 to 60 GPH) Linearity: %1 (8 to 60 GPH)
K Factor Approx. 29,000 K Factor: Approx. 19500
Pressure Drop: 1.2 PSI at 30 GPH
4.8 PSI at 60 GPH
Pressure Drop: .31 PSI at 30 GPH
2.8 PSI at 90 GPH
Working Press: 200 PSI Working Press: 200 PSI
Min. Burst Press: 2000 PSI Min. Burst Press: 2000 PSI
Operating Temp. Range -55
o
C to 70
o
C Operating Temp. Range -55
o
C to 70
o
C
Non Operating Temp. Range: -65
o
C to 100
o
C Non Operating Temp. Range: -65
o
C to 100
o
C
Fuel Ports: 1/4" Female NPT Fuel Ports: 1/4" Female NPT
Instrument P/N 450000-H .
Transducer P/N (FT 4-8AEXS-LEA-2029)
Range: 3 to 120 GPH
Linearity: %1 (9 to 120 GPH)
K Factor Approx. 48,000
Pressure Drop: 0.23 PSI at 30 GPH
0.8 PSI at 60 GPH
Working Press: 1500 PSI
Min. Burst Press: 2000 PSI
Operating Temp. Range -55
o
C to 70
o
C
Non Operating Temp. Range: -65
o
C to 100
o
C
Fuel Ports: AN816-8-8
RS232/422 Input Ports FS-450 .
Single Line Receive Method: RS-232C, RS-423, or 5 Volt Serial.
Protocol: 1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate: Automatic: 9600,4800,1200
Format: Automatic: Aviation Date, Northstar Binary, NMEA-183
RS232 Output Port
Transmit Method: RS-232 Single Line.
Protocol: 1 Start bit, 8 Data bits, 1 Stop bit.
Baud Rate: 9600
Transmit Format: Garmin, Allied Signal, Arnav, UPS