MLO51201 -1-
Contents Description ............................................................................................................3 AZOR kit contents.................................................................................................4 AZ-10K GSM control unit ....................................................................................4 AZ-10D RFID tag reader .....................................................................................5 AZ-10M door-opening detector ................
AZ-10P motion detector power supply (battery lifetime is approx.1 year) coverage dimensions detection angle 120°, covers an area of 10 x 10 m 65 x 95 x 60 mm AZ-10M door-opening detector power supply (lifetime is approx.1 year) reacts to dimensions 2x AAA 1.5V / 1200 mAh alkaline batteries the magnet being withdrawn by 20 mm 32 x 145 x 25 mm + 15 x 55 x 55 mm AZ-10S optical smoke detector power supply reacts to dimensions AA 1.5V / 2600 mAh alkaline battery (lifetime is approx.
Other information AZOR kit contents Time synchronization with a GSM network AZ-10K GSM control unit The GSM control unit, a wireless alarm control panel, processes information from all detectors in the system. It is usually installed in a hidden place. Azor is equipped with the function of the automatic adjustment of the internal clock via a GSM network. The time is saved in the event memory and sent in an informative SMS. Warning: some GSM networks do not provide an exact time signal.
AZ-10S optical smoke detector AZ-10D RFID tag reader Serves for setting and unsetting. It is usually installed at the entrance door. The detector reports fire hazards. It is activated by the presence of smoke or an abnormal temperature increase. Besides sending a report to the system, it also triggers its own siren during an alarm.
AZ-10P motion detector AZ-10P motion detector Reports human motion Internal switches: 1 HIGHER ANALYSIS the detector has increased resistance to false alarms and a slower reaction STANDARD ANALYSIS the detector has standard resistance to false alarms and a standard reaction speed 2 INSTANT REACTION the detector does not provide an entrance delay* DELAY REACTION the detector provides an entrance delay* *) applies only if a “default” reaction is set for the detector – see the A-Link settings Frequent mo
System extension Installation Individually bought devices should be enrolled to Azor using a registration code. The code consists of ten digits and it is in the following format: 123-4567-890. Enrollment (or removal) of a device is performed with a computer. The registration code can be filled into the Serial Number box on the Detectors page. If the registration code is unknown (e.g. damaged label) please use A-Link. Choose the wanted field for enrolling the device and click the Enroll button.
Motion detector installation Settings Azor’s properties can be set using a computer with MS Windows XP or higher. Computer connection You can use a USB cable to connect Azor to the computer. If the computer fails to open the setting program automatically within a certain time after the connection has been established, search for a USB disk named AZOR-USB and launch the A-Link file (click the ) located on the disk. The ALink setting program is equipped with comprehensive icon help for each feature.
RFID tag reader installation Listening in You can trigger listening-in via the voice menu (must be enabled for each user). You can listen to what is happening in the guarded premises for up to 3 minutes. Tips and specifications Do not test listening-in from the same room as the GSM control unit is installed. There is a risk of strong audio feedback between the telephone receiver and Azor’s microphone (listening-in is very sensitive). You can only listen, it is not possible to speak to the premises.
3. 4. Use your telephone to verify the functioning of the SIM card you use in Azor. The card must have the PIN disabled and there must be high quality GSM coverage in the selected area. Insert a SIM card into the GSM control unit (B). Unsetting Azor Press the UNSET button on the RFID tag reader (A) and scan the RFID tag (B) The green LED indicator lights up and the reader confirms its unsetting (2 beeps). Tips and specifications 5. 6.
Control The following description applies to Azor’s default settings. However, you can adjust its behaviour as you wish – see the Settings. Installation of the GSM control unit and its antenna A RFID tag reader is usually used to control Azor at the protected premises. Users whose telephone has been enrolled to the system can also control Azor via the voice menu. The access to the menu can be protected with a personal User’s code – see the Settings.
Enrollment of a telephone Communication test Call Azor from an enrolled telephone (A). The GSM control unit must be switched on and all its indicator lights must be flashing green. Press 9 (C) in the voice menu (B). Detector testing mode should be activated. Activate the detectors and the RFID tag reader one after another (D). Test a motion detector by opening and closing its cover.