User's Manual

Installation manual: OASiS security system JA-82KRC-US 9 / 21 MKH51400
Radio interference indication 26x
261 = YES 260 = NO
NO 30s or longer
Radio communication supervision 27x
271 = YES 270 = NO
NO
RESET enabled 28x
281 = YES 280 = NO
YES
Master control panel enrollment to a sub control
panel for setting (arming) control
290
The sequence triggers
enrollment.
(Un)setting the master control
panel will (un)set the sub control p.
The sub c. panel must be in
enrollment mode.
Master code reset 291
Returns master code to 1234
It has no effect on other codes and
it is recorded in the control panel
memory
Measuring signal strength 298
Activates measurement
arrow keys scroll addresses,
# halts measurement.
Enrolling the control panel to UC, AC or a sub
control panel
299
The sequence triggers
enrollment.
see 12.10
Setting (arming) without an access code 30x
301 = YES 300 = NO
YES by keying: A, B, ABC,
1, 2, 3,4
Triggered detector indication
by text on the keypad display
31x
311 = YES 310 = NO
YES
allows the display
of open windows &
doors,
to view details
press ?
Confirmation of intruder alarms
In this mode, the triggering of an intruder detector in a set
(armed) section will only be recorded to the memory as an
unconfirmed alarm and if then followed by the activation of any
other intruder detector within 40 minutes, an alarm will be
triggered. If the first triggered detector has a DEL reaction and
it is not confirmed by any other detector, it will not trigger an
alarm after the entrance delay has expired.
32x
321 = YES 320 = NO
NO
An alarm can be
confirmed by any
other intruder
detector in any
section which is set
(armed).
Exit delay beeps 33x
331 = YES 330 = NO
YES The last 5 s faster
Exit delay beeps while partially arming 34x
341 = YES 340 = NO
NO The last 5 s faster
(linked to 33x setting)
Entrance delay beeps 35x
351 = YES 350 = NO
YES
Setting (arming) confirmation by wired-siren chirp 36x
361 = YES 360 = NO
NO
IW terminal only
Siren always sounds during audible alarms 37x
371 = YES 370 = NO
YES
NO = siren only
sounds if the system
is completely set
(armed)
Wireless-siren alarms enabled (IW & EW) 38x
381 = YES 380 = NO
YES
Auto-bypass user approval via the
key
If a detector is active during setting (arming), the system will
automatically bypass it (them), immediately (390), or after
keying in
(391)
39x
391 = YES 390 = NO
NO to confirm auto-
bypass while exiting
Service mode press #
twice
Final-door detectors
If this function is used, then Exit & Entrance delay settings are
multiplied by 30s. A triggered final-door detector extends the
exit delay, de-triggering of the last final-door detector ends the
exit delay.
65x
0=none, 1=detectors 01 to 05,
2=detectors 46 to 50
x = 0 If multiple F. door
detectors are used,
then triggered
state=any of them,
non triggered state=all
of them
Partial setting (arming) or system splitting 66x
0 = unsplit system
1 = partial setting (A, AB, ABC)
2 = split system A, B & common
section C (set if A & B are set)
unsplit
Automatic Summer Time (Daylight Saving Time)
680x
6801 = YES 6800 = NO
NO
Changes internal
clock + 1h on Apr.1 &
-1h on Nov.1
Tamper-signal differential indication -
Tamper alarm in response to an increase in the
number of triggered tamper sensors
681x
6811 =
ignore permanently
triggered tamper sensors, i.e.
only react to an increase in
the number of triggered
tamper sensors
6810 =
react with a tamper
alarm to all triggered tamper
sensors
X = 0
Suppresses the
indication of
permanently triggered
tamper sensors
Operating the PG outputs using
8 and
9
682x
6821 = YES 6820 = NO
YES
if yes then arrow keys
can also operate PGX
Permanent alarm status display for a set system
683x
6831 = YES 6830 = NO
NO
suppresses the 3min.
display timeout
Tamper alarm if unset (disarmed)
684x
6841 = YES 6840 = NO
NO
Recording PG output activation to memory
685x
6851 = YES 6850 = NO
YES