Contents : 1. Description .................................................................................................................... 3 1.1. Possibilities of use .............................................................................................. 3 Drilling diagram of TD-101(W) 2. Specifications ................................................................................................................ 3 3. TD-101 includes ............................................................
Conformity: Hereby, Jablotron Ltd., declares that this TD-101(W) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Original of the conformity assessment can be found at the web page www.jablotron.cz, section Technical support. Notes : Although this product does not contain any harmful materials we suggest you to return the product to the dealer or directly to the producer after usage. 1.
11.3. Example of TD-101(W) use with different alarm systems 3. TD-101 includes the dialer, 2.5m telephone cable, set of screws, manual, and emergency F button marking label. Model TD-101W, in addition, includes a wireless remote control (RC-10) 4. Installation We recommend professional installation of the dialer. The dialer should be fixed in the desired location using the two included screws (see drilling diagram at the end of this manual).
11. Examples of TD-101(W) use The dialer inputs are separated with optocouplers, so the variety of possible connections is really wide. The following examples are only for your reference. Other connections and settings are also possible to meet your requirements. Ask you distributor if you need any advice regarding the TD-101 installation or programming. 11.
. Voice & pager messages setting Phone numbers, voice messages and Pager numbers & messages can be set in the USER MODE 6.1. How to open USER MODE Enter User Code (factory setting is 1234) to open the user mode. The user mode is indicated by the green LED. All parameters are programmed in the following sequences. If the first key of the sequence is entered, the red LED will start to flash. When the sequence is completely entered, the red LED will turn off (data will be stored).
6.4. Entering telephone numbers and data for PAGER Telephone numbers and data can be entered in the user mode (the green LED is ON - see 6.1.), entering: DDDD ... D ME where: D E can be to or B i.e. pause. Pause can not be used as a first digit. You can enter a maximum of 26 digits.
6.8. Testing the message sending Sending of voice & Pager messages can be tested in the user mode (the green LED is ON - see 6.1.), entering: FME where: E is the tel. number memory 1 to 6 in which the corresponding message will be sent. If you enter 0 all tel. numbers will be tested. Testing is always audible (you can hear tel. line signals and voice messages from the built in speaker). Example : Voice message no. 1 will be sent to tel. number Mem2 : FM 6.9.
. Trouble shooting • It is impossible to stop the dialing function with the Ekey even if it is enabled in the installer mode. Check if either trigger input IN1 nor IN2 is active (especially if you changed the trigger input logic to a normally closed contact). Additionally, remember that communication with the monitoring station can not be stopped until it is finished.
Ekey is enabled, the TD-101 action can be stopped only if no input is triggered. The dialer 7. Monitoring station data sending If Stop with Function of the TD-101 including the Monitoring Station (MS) communication is demonstrated in the diagram on page 9. Data is sent to the monitoring station before voice & Pager messages are sent (if these messages are used). All parameters of the MS communication should be programmed in cooperation with your monitoring service provider.
8.7. Number of attempts to call monitoring station 7.4. Monitoring station Communication Protocol & Format setting Number of attempts to call MS can be programmed in the installer mode (the yellow LED is ON - see 8.1.), entering: F D D is a number of attempts to call monitoring station, can be from 1 to 8. A successful communication handshake cancels all following attempts. (factory default setting are 3 attempts) Example: Five cycles will be selected : F 8.8.
7.7. Testing the Monitoring Station communication Communication to the MS can be tested in the installer mode (the yellow LED is ON - see 7.1.), entering: FMD E where: D is the tel. number memory 7 or 8 which will be called E means event number (3, 4, 5 or 6) which code will be sent (see item 7.6.) Example: Report code corresponding to IN2 input triggering (activation) will be sent to the main tel. number : FM If only one message is selected (max. 20sec.) : • it should be recorded as message no.