User's Manual

13
PageCreated:05‐04‐2010
Revised:02‐25‐2011
TechnicalManual(076100037818)
NotesRegardingElectricalRequirements
Allelectricalratingsprovidedinthismanualareforreferenceonly.Alwaysrefertothemachinedataplate
togettheexactelectricalinformationforyourmachine.All electrical work performed on machines
shouldbedoneinaccordancewithapplicablelocal,state,territorialandnationalcodes.Workshould
onlybeperformedbyqualiiedelectriciansandauthorizedserviceagents.AlistofauthorizedServiceAgen‐
ciesislocatedinthebackofthismanual.
Note that all electrical wiring used in the dish‐machine must be rated, at a minimum, for 100C (212F).
Furthermore,usecopperconductorsonly.
Whereapplicable,heatingelementamperagedrawshavebeenadjustedfortheassumedinputvoltage.Jack
sonassumesincomingvoltageswillbeeither208,230or460volts.Someoftheheatingelementsusedin
ourmachinesareactuallyratedforothervoltages,suchas240 or 480volts. Alwaysverify the amperage
drawofthemachineinoperationwhensizingcircuitprotection.
Ifyourmachineisequippedwiththeoptionalrinseheater,notetherinseheaterhasitsownelectricalcon‐
nectionandthereforerequiresaseparateservice.Amperageloadsformotorsandheatersarecalledouton
themachinedataplatefortheinstallation/servicetechnician.
Theelectricalconigurationsofthemachinesareasfollows:
AvailableElectricalCharacteristics:
 208volt,60Hz,singlephase
 230volt,60Hz,singlephase
 208volt,60Hz,threephase
 230volt,60Hz,threephase
 460volt,60Hz,threephase
AvailableWashTankHeaters:
 15KW(standardforCREW44)
 18KW(optionalforCREW44,standardforCREW66)
AvailableRinseHeaters(“BoosterHeaters”):
 None(standard)
 12KW(40Friseintemperature)
 18KW(70Friseintemperature)