INSTALLATIONINSTRUCTIONS(CONTINUED)
stalledontheincomingwaterline.Thispreventswaterhammer(hydraulicshock),inducedbythesolenoid
valveasitoperates,fromcausingdamagetotheequipment.
CONNECTINGTHE DRAINLINE: The drainfor the unit isa gravity discharge drain. Allpipingtothe
machinedrainmustbeaminimum1‐1/2”NPTANDSHALLNOTBEREDUCED.Theremustalsobeanair
gapbetweenthemachinedrainlineandtheloorsinkordrain.Ifagreasetrapisrequiredbycode,itshould
havealowcapacityof30gallons.44”unitshaveonedrainconnectionpoint.66”unitshavetwopoints.
STEAMLINECONNECTIONS:Somemachinescoveredinthismanualaredesignedtouselowpressure
steamasasourceofheatforthewashtank.Thosemachinescomewithlinesbywhichanoutsidesourceof
steam(i.e.steambooster)isconnected.Connectallsteamlinesfromtheboostertothemachineinaccord‐
ancewiththeboostermanufacturer’sinstructions.Ensurethatallapplicablecodesandregulationsaread‐
heredto.Seethemachinedataplateforinformationrelatedtosteamlowrequirements.
ELECTRICALPOWERCONNECTIONS:Allelectricalconnectionsaretobemadeinaccordancewithap
plicableportionsoflocal,state,territorialandnationalcodes.
DISCONNECTELECTRICALPOWERSUPPLIESANDTAGOUTINACCORDANCEWITHAPPROPRIATE
PROCEDURESANDCODESATTHEDISCONNECTSWITCHTOINDICATEYOUAREWORKINGONTHATCIR-
CUIT.
Thismanualprovidesreferenceinformationregardingelectricalrequirementsandloads,butthatinfor‐
mationmay changewithoutnotice. Alwaysreferto themachinedata platefor voltage requirements, ma‐
chinevoltage,totalamperageloadandserialnumber.Ifyoucannotreadyourdataplatebecauseithasbeen
damaged,youshouldcontactthemanufacturer.
Themainpowerterminalblocks(forthedish‐machineandfortherinseboosterheater,ifapplicable)
are locatedat the topof the machine.You will haveto remove thetopcover toaccessthese connections.
Routeincomingpowerlineswithinconduitthatwillconnectviaittingstotheprepunchedholesinthe
backoftheunit.Installpowerandgroundwirestolugsasindicatedbytheappropriatedecalsinthecontrol
box.Usecopperconductorsonly.Useofaantioxidationagentis permissible on the power connections.
Tightenallconnections.
Verifytheincomingvoltagematchesthevoltageindicatedonthedecalnexttotheincomingpowerpre‐
punchedhole.
Pleasenote thedish‐machinehasaseparatepower connectionfromtherinseboosterheaterandthe
circuit protection requirementsare different for each.Refertothemachine data plate forinformation on
minimumcircuitprotection.
DISHMACHINEVENTILATION:Thedish‐machineshouldbelocatedwithprovisionsforventingintoan
adequateexhausthoodorventilationsystem.Thisisessentialtopermiteficientremovalofthecondensa‐
tionexhaust.Ensuretheexhaustsystemisacceptableinaccordancewithapplicablecodesandstandards.