JPX-300 UNDERCOUNTER DISHMACHINE SERIES INSTALLATION & OPERATION MANUAL FOR JACKSON MODELS: JPX-300H JPX-300HC JPX-300HN JPX-300L An March 06, 2007 P/N 7610-002-71-26 (Revision J) Company Jackson MSC Inc. P.O. BOX 1060 HWY. 25E BARBOURVILLE, KY. 40906 PHONE (606) 523-9795 FAX (606) 523-9196 www.jacksonmsc.
MANUFACTURERS WARRANTY ONE YEAR LIMITED PARTS & LABOR WARRANTY ALL NEW JACKSON DISHWASHERS ARE WARRANTED TO THE ORIGINAL PURCHASER TO BE FREE FROM DEFECTS IN MATERIAL OR WORKMANSHIP, UNDER NORMAL USE AND OPERATION FOR A PERIOD OF (1) ONE YEAR FROM THE DATE OF PURCHASE, BUT IN NO EVENT TO EXCEED (18) EIGHTEEN MONTHS FROM THE DATE OF SHIPMENT FROM THE FACTORY.
STOP! PARE! ARRET! CALL 1-888-800-5672 TO REGISTER THIS PRODUCT! FAILURE TO DO SO WILL VOID THE WARRANTY! LLAME AL 1-888-800-5672 PARA REGISTRAR ESTE PRODUCTO! AL NO HACERLO LA GARANTIA SERA ANULADA! S.V.P.
REVISION REVISION DATE MADE APPLICABLE BY ECN A 01-30-03 MAW 6641 Release to production B 02-26-03 MAW N/A Updated operation instructions C 04-22-03 CBW N/A Added JPX-300HN D 04-12-04 MAW N/A Converted to new layout. Added specifications for JPX-300HN 115 Volt. E 01-27-05 MAW 7068 Added Deliming Instructions. Add dimension drawing for JPX300L. Removed JPX-300L model designation. Added JPX-300HC model. F 08-25-05 MAW 7310 Added JPX-300HN dimensions drawing.
NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL JPX-300HN JPX-300H = High temperature, hot water sanitizing, with a booster tank. JPX-300HC = High temperature, hot water sanitizing, with a booster tank, and a cycle counter. JPX-300HN = High temperature, hot water sanitizing, with no booster tank. JPX-300L = Low temperature with chemical feeder pumps. Jackson MSC Inc. provides technical support for all of the dishmachines detailed in this manual.
TABLE OF CONTENTS SECTION I. II. III. IV. V.
SECTION 1: SPECIFICATION INFORMATION 1
SECTION 1: SPECIFICATION INFORMATION SPECIFICATIONS of the JPX-300H/JPX-300HC/JPX-300HN PERFORMANCE/CAPABILITIES OPERATING CAPACITY (RACKS/HOUR) ELECTRICAL REQUIREMENTS RACKS PER HOUR 30 DISHES PER HOUR 600 GLASSES PER HOUR 600 WASH MOTOR HP NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here.
SECTION 1: SPECIFICATION INFORMATION SPECIFICATIONS of the JPX-300L ELECTRICAL REQUIREMENTS PERFORMANCE/CAPABILITIES WASH MOTOR HP OPERATING CAPACITY (RACKS/HOUR) RACKS PER HOUR 24 DISHES PER HOUR 600 GLASSES PER HOUR 600 NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here.
SECTION 1: SPECIFICATION INFORMATION JPX-300H/HC DIMENSIONS LEGEND A - Water Inlet 1/2” Female Pipe Thread, 2 1/2” AFF B - Chemical Feeder Connection C - Electrical Connection D - Rinse Additive Connection E - Drain Connection Flexible Hose 6’ Free Length, 1” ID x 1 3/8” OD 12” (30.5 cm) C 19” (48.3 cm) 22 5/8” (57.5 cm) 16 3/4” (42.5 cm) 6 1/2” (16.5 cm) 24” (60.9 cm) 4 1/2” (11.4 cm) 33 1/4” (84.5 cm) 13 1/4” (33.7 cm) 8 1/2” (21.6 cm) 4 5/8” (11.7 cm) 4 1/4” (10.8 cm) 2 1/4” (5.
SECTION 1: SPECIFICATION INFORMATION JPX-300HN DIMENSIONS 2 1/2” (6.4 cm) Min. Wall Clearance LEGEND A - Water Inlet 1/2” ID Female Pipe Thread, 2 1/2” AFF B - Detergent Feeder Connection C - Electrical Connection D - Drain Connection Flexible Hose 6’ Free Length, 1” ID x 1 3/8” OD E - Rinse Additive Connection E 12” (30.5 cm) 19” (48.3 cm) C 22 5/8” (57.5 cm) A DOOR OPEN D 16 3/4” (42.5 cm) 6 1/2” (16.5 cm) E 24” (60.9 cm) 4 1/2” (11.4 cm) B C 8 1/2” (21.6 cm) 2 1/4” (5.
SECTION 1: SPECIFICATION INFORMATION JPX-300L DIMENSIONS 2-21" Minimum Wall Clearance D LEGEND A - Detergent Feeder Connection B - Electrical Connection C - Water Inlet 1/2” Female Pipe Thread, 2 1/2” AFF D - Rinse Additive Connection E - Drain Connection Flexible Hose 6’ Free Length, 1” ID x 1 3/8” OD B 12" 19” 19" (48.3 cm) 22 5/8” 22-5/8" (57.5 cm) 3 3/4” (9.5 cm) C 24” 24"cm) (60.9 D E 24” (61 cm) A 33 1/4” (84.5 cm) B 33-1/4" 12 13/16” (84.5 cm) 12-13/16" 8-1/2" 8 1/2” (21.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS 7
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VISUAL INSPECTION: Before installing the unit, check the container and machine for damage. A damaged container is an indicator that there may be some damage to the machine. If there is damage to both the container and machine, do not throw away the container. The dishmachine has been inspected and packed at the factory and is expected to arrive to you in new, undamaged condition.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS ELECTRICAL INSTALLATION INSTRUCTIONS SHOCK ABSORBER: It is also recommended that a shock absorber (not supplied with the JPX-300 series models) be installed in the incoming water line. This prevents line hammer (hydraulic shock), induced by the solenoid valve as it operates, from causing damage to the equipment.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CHEMICAL DISPENSING EQUIPMENT WARNING: CHLORINE-BASED SANITIZERS CAN BE DETRIMENTAL TO YOUR MACHINE IF THE CHEMICAL SOLUTION IS TOO STRONG. SEE YOUR CHEMICAL PROFESSIONAL TO ENSURE YOUR DISPENSER IS SET UP CORRECTLY. This equipment is not recommend for use with deionized water or other aggressive fluids. Use of deionized water or other aggressive fluids will result in corrosion and failure of materials and components.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS PROGRAMMING INSTRUCTIONS FOR CHEMICAL FEEDER PUMPS (FOR INSTALLATION TECHNICIAN ONLY) To access the programming mode, the machine must be ON, and idle (between cycles). On the timer board, press and hold both the MOVE and ENTER buttons on the timer board simultaneously for two seconds. The PROGRAM (PGM) light and light A will illumniate.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS DETERGENT CONTROL Detergent usage and water hardness are two factors that contribute greatly to how efficiently your dishmachine will operate. Using detergent in the proper amount can become, in time, a source of substantial savings. A qualified water treatment specialist can tell you what is needed for maximum efficiency from your detergent, but you should still know some basics so you’ll understand what they are talking about.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS PREPARATION: Before proceeding with the start-up of the unit, verify the following: 1. The strainer is in place and is clean. 2. That the wash and rinse arms are screwed securely into place and that their endcaps are tight. The wash and rinse arms should rotate freely. 3. Verify all chemical levels for machine chemical feeder pumps are correct. POWER UP: To energize the unit, turn on the power at the service breaker.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS OPERATION INSTRUCTIONS (CONTINUED)/DELIMING INSTRUCTIONS SHUTDOWN AND CLEANING: At the end of the workday, close the door. Start a cycle. Wait approximately five seconds after the green auto light comes on and then push the POWER OFF switch. This will put the machine in shutdown mode which will let the machine drain completely prior to shutting off. Once the wash tub is drained and power light is off, remove he pan strainer.
SECTION 3: PREVENTATIVE MAINTENANCE 15
SECTION 3: PREVENTATIVE MAINTENANCE PREVENTATIVE MAINTENANCE The dishmachines covered in this manual are designed to operate with a minimum of interaction with the operator. However, this does not mean that some items will not wear out in time. Jackson highly recommends that any maintenance and repairs not specifically discussed in this manual should be performed by QUALIFIED SERVICE PERSONNEL ONLY. Performing maintenance on your dishmachine may void your warranty if it is still in effect.
SECTION 4: ELECTRICAL SCHEMATICS 17
SECTION 4: ELECTRICAL SCHEMATICS JPX-300HN 115 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300HN (FOR USE WITH STAINLESS STEEL SWITCHES) 115 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300HN (UNIVERSAL TIMER & SS SWITCHES) 115 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H/JPX-300HN 208-230 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H/HN (FOR USE WITH STAINLESS STEEL SWITCHES) 208-230 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H/HN (S/S SWITCHES & CONTACTOR) 208-230 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H/HN (UNIVERAL TIMER & SS SWITCHES) 208-240 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H 460 VOLT - 60 HERTZ - THREE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H (FOR USE WITH STAINLESS STEEL SWITCHES) 460 VOLT - 60 HERTZ - THREE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H (UNIVERSAL TIMER & SS SWITCHES) 460 VOLT - 60 HERTZ - THREE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H (EXTENDED WASH) 460 VOLT - 60 HERTZ - THREE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300H (EXTENDED WASH) (FOR USE WITH STAINLESS STEEL SWITCHES) 460 VOLT - 60 HERTZ - THREE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300HC 208-230 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300HC (FOR USE WITH STAINLESS STEEL SWITCHES) 208-230 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300HC (UNIVERSAL TIMER & SS SWITCHES) 208-230 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300L 115 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300L (FOR USE WITH STAINLESS STEEL SWITCHES) 115 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300L (UNIVERSAL TIMER & SS SWITCHES) 115 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 4: ELECTRICAL SCHEMATICS JPX-300L (UNIVERSAL TIMER & SS SWITCHES) 208-230 VOLT - 60 HERTZ - SINGLE PHASE JPX-300 Installation/Operation Manual 7610-002-71-26 Rev.
SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS 37
SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS ALABAMA TO GEORGIA ALABAMA: CALIFORNIA: JONES-McLEOD APPLIANCE SVC 1616 7TH AVE. NORTH BIRMINGHAM, AL 35203 (205) 251-0159 800-821-1150 FAX: (205) 322-1440 service@jones-mcleod.com BARKERS FOOD MACHINERY SERVICES 5367 SECOND STREET IRWINDALE, CA 91706 (626) 960-9390 800-258-6999 FAX: (626) 337-4541 service@barkers.com JONES-McLEOD APPLIANCE SVC 854 LAKESIDE DRIVE MOBILE, AL 36693 (251) 666-7278 800-237-9859 FAX: (251) 661-0223 GCS SERVICE INC.
SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS HAWAII TO MINNESOTA HAWAII: IOWA: LOUISIANA: MASSACHUSETTS: FOOD EQMT. PARTS & SERVICE CO. 300 PUUHALE RD. HONOLULU, HI 96819 (808) 847-4871 FAX: (808) 842-1560 fepsco@hula.net GOODWIN TUCKER GROUP 2900 DELAWARE AVENUE DES MOINES, IA 50317 (515) 262-9308 800-372-6066 FAX: (515) 262-2936 parts@goodwintucker.com BANA PARTS INC. 1501 KUEBLE STREET HARAHAN, LA 70123 (504) 734-0076 800-325-7543 FAX: (504) 734-8456 ACE SERVICE CO. 95 HAMPTON AVE.
SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS MISSISSIPPI TO NEW YORK MISSISSIPPI: FAX: (702) 649-4607 larry@hitechnv.com GCS SERVICE INC. JACKSON, MS (601) 956-7800 800-274-5954 FAX: (601) 956-1200 5454 LOUIE LANE RENO, NV 89511 (775) 852-9696 FAX: (775) 852-5104 GCS SERVICE INC. MEMPHIS, TN (901) 366-4587 800-262-9155 FAX: (901) 366-4588 GCS SERVICE INC. LAS VEGAS, NV (702) 450-3495 800-500-9060 FAX: (702) 450-3491 MISSOURI: NEW HAMPSHIRE: GCS SERVICE INC.
SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS NORTH DAKOTA TO UTAH NORTH DAKOTA: FAX: (405) 236-5592 SOUTH CAROLINA: GCS SERVICE INC. MINNEAPOLIS, MN (612) 546-4221 800-345-4221 FAX: (612) 546-4286 OREGON: AUTHORIZED APPLIANCE SERVICECENTER 1811 TAYLOR ST. COLUMBIA, SC 29202 (803) 254-8414 FAX: (803) 254-5146 OHIO: CERTIFIED SERVICE CENTER 890 REDNA TERRACE CINCINNATI, OH 45215 (513) 772-6600 800-543-2060 FAX: (513) 612-6600 sbarasch@certifiedsc.com CERTIFIED SERVICE CENTER 171J-K NORTH HAMILTON RD.
SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS VERMONT TO WYOMING/CANADA VERMONT: WEST VIRGINIA: CANADA NORTHERN PARTS & SVC. 4874 S. CATHERINE STREET PLATTSBURGH, NY 12901 (518) 563-3200 800-634-5005 FAX: (800) 782-5424 info@northernparts.com STATEWIDE SERVICE, INC. 603 MAIN AVE. NITRO, WV 25143 (304) 755-1811 (800) 441-9739 FAX: (304) 755-4001 sws3182@aol.com GCS SERVICE INC.