  Assemble in accordance with the local plumbing or 
building codes. 
1.  Identify drain overow kit provided with your bathtub. 
  Remove and open the overow package and conrm 
  that all parts are present.
2.  Remove washers and nuts from the overow tting.
3.  Place a small bead of plumbers putty, silicone, or   
  similar approved sealant around the underside of the 
  top ange of the overow tting. 
4.  Place the overow tting into the overow hole of the 
  bathtub (Figure 4).
5.  From the underside of the unit, place the rubber washer 
  then locknut on the overow tting and tighten securely. 
  Be careful not to overtighten.
6.  Assemble the remaining drain pieces as shown in the 
 illustration. 
7.  After the drain is fully installed, test for proper drainage. 
  If the unit does not drain properly, rectify this condition 
  before proceeding with further bathtub installation.
  Watertight installation of the drain and overow   
    is the installer’s responsibility. Drain leakage is   
    excluded from the Jacuzzi Luxury Bath warranty of 
 this product.
  OPTIONAL - If the Fuzion
®
 Wood Frame is not 
  being used, please proceed to Step 2 in the 
  Undermount Installation section on page 11.
Fig. 4
Overow Fitting
Apply sealant/caulking 
(commercially available)
Flat Rubber 
Washer
Lock Nut
Direct Waste Overow Drain
Fuzion
®
 Specic Material
 Fuzion
®
 Overow Drain Installation
Figure 4 - Overow Installation
The additional design features of the Fuzion
®
 require that the following steps be completed prior to installing the bathtub 
in the constructed surround. The following steps must also be completed in the order specied:
1.  Fuzion
®
 Faucet Installation
2.  Fuzion
®
 Overow/Drain Installation
3. Fuzion
®
 Wood Frame Installation
4. Fuzion
®
 Control Panel Installation
 Fuzion
®
 Faucet Installation
  Selecting a faucet for rim mounting: The combined thickness at the rim of the bathtub shell and optional 
wood deck is 2˝ (50mm) nominal. The length of the faucet tailpiece(s) must be long enough to extend past 
this dimension and have ample clearance to assemble any hardware (i.e. locknut, water supply fittings, etc.) 
necessary for installation. For undermount units, the combined thickness of the bathtub shell is ½˝ (12mm) 
nominal and the undermount deck should not exceed the length of the faucet tailpiece(s), including any 
assembly hardware.
Overow Drain  
Assembly
Direct Waste 
Overow Drain
Waste Elbow
Twist and Turn  
Drain Assembly
PVC Pipe
PVC Pipe
PVC Flex Pipe
PVC Flex Pipe
PVC Flex Pipe
PVC 45 Elbow
PVC 45 
Elbow Street
PVC 45 Elbow Street
PVC 45 Elbow