Use and Care Guide

HEATER
FIELD WIRING
JUNCTION BOX
OPTIONAL:
30 MINUTE TIMER
(SINGLE POLE SWITCH)
WALL MOUNTED
ON/OFF SWITCH
FUSED DISCONNECT SWITCH
OR CIRCUIT BREAKER
NL1LIVENEUTRAL
WIRING DIAGRAM RAPIDHEAT
(CANADA ONLY)
DO NOT OPERATE THE WHIRLPOOL BATH UNLESS
THE HEATER IS CONNECTED TO A CLASS A GFCI
(GROUND FAULT CIRCUIT INTERRUPTOR). TEST
THE GFCI AT LEAST ONCE A MONTH.
120V SINGLE PHASE POWER SUPPLY
PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPTOR
G
N
MOTOR
L1
FIELD WIRING
JUNCTION BOX
OPTIONAL:
30 MINUTE TIMER
(SINGLE POLE SWITCH)
WALL MOUNTED
ON/OFF SWITCH
FUSED DISCONNECT SWITCH
OR CIRCUIT BREAKER
NL1LIVENEUTRAL
WIRING DIAGRAM BATH
(CANADA ONLY)
DO NOT OPERATE THE WHIRLPOOL BATH UNLESS
IT IS CONNECTED TO A CLASS A GFCI (GROUND
FAULT CIRCUIT INTERRUPTOR). TEST THE GFCI AT
LEAST ONCE A MONTH.
120V SINGLE PHASE POWER SUPPLY
PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPTOR
G
G
Electrical Connections (Canada only)
The electrical installation is subject to inspection and approval by the local inspection authority. Employ a licensed electrician to connect the
equipment to the supply in accordance with the local electrical code. Check that the power supply available corresponds to that required by the
motor.
The whirlpool bath must be connected to a separate 120VAC, 15AMP, single-phase circuit or a separate 120VAC, 20AMP, single-phase circuit
(refer to the table for your model). The RapidHeat heater must be connected to a separate 120VAC, 15AMP, single-phase circuit. Use No. 14
AWG wire, or heavier, to run a separate fused circuit from the distribution panel. Note that protection of the circuit by a ground fault circuit interrupter
is mandatory under the Canadian Electrical Code, Part 1, Section 68. Ground fault circuit interrupters are available from your local electrical supplier.
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit Interrupter.
CAUTION: Operating the motor/pump without enough water in the bath can cause leaking and permanent damage to the pump. Before
power is applied to the installation, make sure the switch is in the OFF position to avoid pump damage.
16