Installation Guide

Salon™ Spa Bath
Page 18 www.jacuzzi.com Installation and Operation
English
Pulse Mode
With the blower ON, press the pulse button to cycle
between off and a user dened maximum.
The blower will cycle on (1.5 seconds) to the user dened
maximum (1.5 seconds). All four indicator lights will blink. To
turn off pulse mode, press the (pulse) button.
Press the (+) or (-) button while in pulse mode to set the
maximum intensity level from 50%-100%. There is a 5
second delay after adjusting the maximum intensity level
before changes are observed.
If the wave or pulse functions do not immediately operate
when the wave button or pulse button is pressed, you may
be in chromatherapy lighting mode, you must rst press
blower button to switch to blower operation.
These lights will
be blinking
Drain Assist Purge
The purge cycle is automatic and will reduce excessive accumulation of residual water in the air channels.
There are two purge cycles, drain assisted purge and daily purge.
The purge cycle is sensor assisted – two sensors (metal dials) are located near the drain of the bathtub. The sensors
detect the presence and absence of water in the bathtub.
To ensure effective and correct operation of the water sensors, it is important to keep them clean and free from
blockage or objects.
After bathing and following the emptying of the bathing well, the sensors detect a “no water” condition. A ve minute
wait time elapses and then the blower is activated. The blower will cycle through a range of speeds for 2 ½ minutes,
during which either 2 or 3 indicator lights will ash at various speeds.
The purge cycle will engage even if the blower is not used during bathing.
The cycle may initiate more than once if the sensors become wet during any part of the purge operation or during
routine cleaning of the bathtub. This is normal and does not require attention.
Purging Air Channels
Each day, the blower will automatically activate a daily purge. The blower will operate for one minute on high power,
followed by 15 seconds at ½ power.
To set purge time:
Wait until the time which you desire the daily purge to activate, with the blower off, press and hold the plus button for
ve seconds. To conrm that you have set the time, the blower will cycle between on and off 2 times in a 4 second
span.
To cancel daily purge:
With the blower off, press and hold the plus button for ve seconds. To conrm that you have cancelled the purge, the
blower will come on for 1 second and then stop.
YOU MUST SET THE DAILY PURGE UPON INSTALLATION; THE DEFAULT IS NO PRE-SET DAILY PURGE.
If a power failure occurs, the system will default to no daily purge cycle.
Daily Purge