owner’s manual J-300™ J - 315 J - 325 J - 335 J - 345 J - 355 J - 365 J - 375 2530-398U Rev.
Attention New Spa Owner! Congratulations on the purchase of your new Jacuzzi® spa! The following is a list of automated functions performed by your spa. These functions are listed below in an attempt to alleviate any operational concerns you may have during the first 24-hours of ownership! Also listed below are important maintenance recommendations you should observe on a regular basis to protect your new investment.
Table of Contents 1.0 2.0 Important Spa Owner Information ������������������������������������1 FCC Notice ��������������������������������������������������������������������������1 3.0 Important Safety Instructions for all Spa Owners �����������2 3.1 3.2 3.3 3.
12.0 Spa Maintenance ��������������������������������������������������������������30 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.
J-300 Series J-300 Series 1.0 Important Spa Owner Information Your Jacuzzi® J-300 Series spa is constructed to the highest standards and is capable of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the spa for efficient operation, an uncovered spa surface directly exposed to sunlight and high temperatures for an extended period is subject to permanent damage. Damage caused by exposing the spa to this abuse is not covered under warranty.
J-300 Series 3.0 Important Safety Instructions for all Spa Owners READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY! This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB Safety Act). When installing and using this spa, basic safety precautions should always be followed, including: ! DANGER: Risk of Severe Injury or Drowning! 1. • Extreme caution must be exercised to prevent unauthorized access by children.
J-300 Series J-300 Series • • • • • • on the grounding lug, inside the equipment compartment on the equipment box. A grounding wire connector is provided on this unit to connect a minimum No. 8 AWG (8.4 mm²) solid copper conductor between this unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit. Never permit any electrical appliance, such as a light, telephone, radio, television, etc. within 5 feet (1.
J-300 Series ! WARNING: Risk of Severe Injury or Death! 6. • Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, if pregnant or possibly pregnant, consult your physician before using a spa. • Pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
J-300 Series J-300 Series 9. CAUTION: To DECREASE Risk of Product Damage. • Maintain water chemistry in accordance with manufacturer’s instructions. • Proper chemical maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components. 10. NOTE: This spa is not intended nor designed to be used in a commercial or public application.
J-300 Series 3.1 Entrapment Risk The Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) to drain and/or suction fittings causing death, drowning, or serious injury (see diagram below). This spa was manufactured to meet the standards and specifications outlined in the “Virginia Graeme Baker Pool and Spa Safety Act” (VGB Safety Act). Entrapment risk can be minimized if proper precautions are taken.
J-300 Series J-300 Series 3. • DANGER: Risk of Severe Injury or Drowning! Body entrapment: May occur when part of the torso becomes entrapped, inserted or sucked into a suction or outlet opening. Never allow children to play or get near the suction fittings, suction covers, filter, filter lid or skimmer assembly. ! ! DANGER: Risk of Severe Injury or Drowning! 4. Evisceration (disembowelment) entrapment: May occur when the buttocks becomes entrapped, inserted or sucked into a suction or outlet opening.
J-300 Series 3.3 Important Additional CSA Safety Instructions (Canada Only) When using this electrical equipment, basic safety precautions should always be followed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. A green colored terminal or a terminal marked G, Gr, Ground, Grounding or the symbol* is located inside the supply terminal box or compartment.
J-300 Series J-300 Series 4.0 Choosing A Location IMPORTANT: Because of the combined weight of the spa, water and users, it is extremely important that the base upon which the spa rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the spa is in place. If the spa is placed on a surface which does not meet these requirements, damage to the skirt and/or the spa shell may result.
J-300 Series 4.1 Outdoor Location In selecting the ideal outdoor location for your spa, we suggest that you take into consideration: • • • • • • The proximity to changing area and shelter (especially in colder weather). The pathway to and from your spa (this should be free of debris so that dirt and leaves are not easily tracked into the spa). The closeness to trees and shrubbery (remember that leaves and birds could create extra work in keeping the spa clean).
J-300 Series J-300 Series • Sufficient Access: In the unlikely event that you should ever need to access or gain entry to any portion of the spa for servicing, it is highly recommended that you plan your indoor installation to provide full access to the entire spa. • Warranty: Damage caused by not following these guidelines or any improper installation not in accordance to local codes or authorities is not covered under the spas warranty. Please consult your local state or city building ordinances.
J-300 Series 5.0 General Electrical Safety Instructions Your new Jacuzzi® spa is equipped with a “state-of-the-art” equipment system. It contains the most advanced safety and self-protective equipment in the industry. Nonetheless, this spa must be installed properly to insure dependable usage. Please contact your dealer or local building department should you have any questions regarding your installation. Proper grounding is extremely important. Jacuzzi spas are equipped with a current collector system.
J-300 Series J-300 Series North American J-335, J-345, J-355, J-365 and J-375 Models (60 Hz) Circuit Breaker (2-Pole): Number of Wires: Frequency: Current Draw: 240V/40A* 240V/50A** 240V/60A*** 40A 50A 60A 3 3 3 60 Hz 60 Hz 60 Hz 26A 36A 45A In 40A configuration, the heater will not operate while either jets pump is running in high speed. Note: pump 2 runs only in high speed. In 50A configuration, the heater will not operate while both jets ** pumps are running in high speed.
J-300 Series Export J-335, J-345, J-355, J-365 and J-375 Models (50 Hz) Circuit Breaker: Number of Wires: Frequency: Current Draw: 230V/20A* 230V/30A** 230V/40A*** 20A 30A 40A 3 3 3 50 Hz 50 Hz 50 Hz 15A 23A 29A In 20A configuration, the heater will not operate while either jets pump is running in high speed. This is the factory setting. Note: pump 2 runs only in high speed. In 30A configuration, the heater will operate while one jets pump ** is running in high speed.
J-300 Series J-300 Series 7.0 Electrical Wiring Instructions IMPORTANT NOTICE: The electrical wiring of this spa must meet the requirements of the National Electrical Code/USA (NEC) and any applicable state or local codes. The electrical circuit must be installed by a qualified electrician and approved by a local building/ electrical inspection authority. 1. Convertible 120/240V Power Models: • • DANGER: To DECREASE the risk of shock, product damage or electrical fire.
J-300 Series ANSI/NFPA 70. The disconnecting means must be readily accessible to the spa’s occupant but installed at least 5 feet (1.5m) from spa water. 7. The electrical circuit supplied for the spa must include a suitable ground fault circuit interrupter (GFCI) as required by NEC/USA Article 680-42. 8. To gain access to the spa’s power terminal block, remove the screws securing the synthetic cabinet panel under the control panel (Figure A). Then remove the four control box door screws and door (Figure B).
J-300 Series J-300 Series Figure B Control Box 2 TB1 1 3 1. Terminal Block 2. Bonding Lug 3.
J-300 Series 8.0 Spa Fill Up Procedure For best results, read each step in its entirety before proceeding with that step. 1. Prepare The Spa For Filling • Clear all debris from the spa. (Although the spa shell has been polished at the factory, you may want to treat it with a specially formulated spa cleaner.) Consult your authorized Jacuzzi dealer for additional information prior to filling spa. • Remove filter cover, then remove filter cartridge as outlined in section 12.1 (page 30). 2.
J-300 Series J-300 Series ! WARNING: Risk of poisoning or death. Never leave chemicals opened and accessible to anyone. Use chemicals according to the vendors instructions. Always store chemicals in a safe and/or locked location. Keep away from and out of reach of children. 6. Establish A Stable Sanitizer Reading Establish a stable sanitizer reading between 3.0-4.0 ppm chlorine or 2.04.0 ppm bromine.
J-300 Series 8. Place Cover On Spa • Keeping the insulating cover in place anytime the spa is not in use will reduce the time required for heating, thereby minimizing operating costs. • The time required for initial heat-up will vary depending on the starting water temperature. ! DANGER: Risk of PERSONAL injury. Check water temperature carefully before entering hot tub! Excessive water temperature can cause burns, welts and body temperature to rise, hyperthermia (over-heating).
J-300 Series J-300 Series 10. Leave spa cover open during this step to allow excessive chemical vapors to exit spa, protecting pillows and plastic knobs from chemical attack. If spa is indoors, open doors and windows for proper ventilation. Turn on all jet pumps for one hour, then place the massage selector knob in the center “combo” position and open all air controls.
J-300 Series ! WARNING: RISK OF PERSONAL INJURY. • • To decrease the risk of injury, entrapment or drowning, never leave your hot tub unattended for any reason, especially if while the cover is open and accessible to small children and animals! To decrease the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water chemistry within 6 step parameters.
J-300 Series J-300 Series 9.0 Control Functions 9.1 Control Panel A. LED Display: Can display current water temperature (default display), water temperature set point, selected filtration/ heating mode, and error messages. A H G F B C D E 2-Pump Control Panel Shown B. Warmer ( ) Button: Increases water temperature set point. C. Cooler ( ) Button: Decreases water temperature set point. D.
J-300 Series 9.2 General Spa Features And Controls 13 2 2 13 11 17 17 4 7 2 6 16 18 10 16 10 5 3 10 9 6 8 12 2 18 18 5 5 17 17 2 15 13 1 13 14 J-365 model illustrated - Location of Features Varies by Model. Specifications/ features subject to change without notice. 1. Control Panel 2. Toggle Air Controls 3. Filter/Skimmer Grill 4. PowerPro MX Jets 5. Therapy Jets 6. Massage Selector Valves 7. Therapy Seat 8. Spa Light 9. Vertical Jets (Foot Jets) 10.
J-300 Series J-300 Series 10.0 Operating Instructions The spa control system has automatic functions that operate upon start-up and normal operation to protect the system. Upon power up, the readout displays the following information: 1. Control panel displays current software release (e.g. 3.56), then; 2. Control panel displays “888” and all indicator LEDs are lit, permitting visual inspection of all display segments and indicator lights for proper operation. 1. 2. 3. 3.
J-300 Series 10.4 Light Mode Button This button offers 4 light modes for your enjoyment. Press this button to select your favorite lighting effect as follows: Press Once Press Again Press Again High-Speed Color Blend Mode: Displays hundreds of colors in 5 second intervals. Low-Speed Color Blend Mode: Displays hundreds of colors in 20 seconds intervals. Freeze Color Blend Mode: Selects or “freezes” your low speed blending color of choice.
J-300 Series J-300 Series 10.7 Selecting Desired Massage Action B C All models incorporate a massage selector valve that allows you to customize the massage and performance by A diverting water between various jet systems within the spa. Simply turn valve to positions A, B or C to divert water pressure to various jet groups. Note: The valve is intended to operate in positions A (Combo), B, or C for optimum performance.
J-300 Series 11.0 Automatic Filtration Cycles Your new spa includes a 24-hour circulation pump which filters the water continuously. The circulation pump draws water through the skimmer bag and one of two filter cartridges to effectively remove small debris in your spa. Note: The 24-hour circulation pump system also supplies heated water to the spa when the heater turns on.
J-300 Series J-300 Series Standard Filtration/Heating Modes F0 5 minutes of filtration per day (one 5 minute “Blow-Out” cycle every 24 hours to purge all plumbing lines) F1 1 hour of filtration per day (one 30-minute cycle every 12 hours); This is the factory default setting. F2 1.
J-300 Series 12.0 Spa Maintenance Proper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Jacuzzi dealer can supply you with all the information, supplies, and accessory products you will need to accomplish this.
J-300 Series J-300 Series An optional chemical feeder is available through your authorized Jacuzzi dealer that installs under the filter cap (#2472‑673). Always remove the chemical feeder cap and feeder (when used) during the filter cleaning process by turning the cap handle counterclockwise. Reinstall the cap and feeder back onto the filter cartridge after the filter cleaning process is complete.
J-300 Series F G Trapped Air Bubbles C ar tri dg e 2 C ar tri dg e 1 E Lift unthreaded filter cartridge from skimmer well. H If used, remove the chemical feeder as instructed prior to rinsing the filter cartridges. Rinse debris from filter pleats on each cartridge using a garden hose and high pressure nozzle. Start at the top and work downward towards handle. Repeat until all pleats are clean. I Submerge both filter cartridges in spa.
J-300 Series J-300 Series Periodically, the filter cartridge will need a more thorough cleaning to remove imbedded oils and minerals. For this, we suggest cleaning as illustrated in step “F”, followed by soaking the filter overnight in a plastic container filled with a solution of water and specially formulated filter cleanser available from your authorized Jacuzzi dealer. The average life expectancy of each filter is approximately two years with proper care and water quality maintenance.
J-300 Series 12.3 Pillow Care Remove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. To maintain water resistance and luster, apply a quality vinyl conditioner once a month. Always remove the pillows when adding chemical shock treatment to the spa water. When the sanitizer reading is below 4.0 ppm, pillows can be reinstalled.
J-300 Series J-300 Series CAUTION: Never spray cabinet with a garden hose for any reason since this action may induce an electrical short in the spa’s electrical equipment. 12.7 Winterizing Your Jacuzzi® spa is designed to automatically protect itself against freezing when operating properly. During periods of severe freezing temperatures, you should check periodically to be certain that the electrical supply to the spa has not been interrupted.
J-300 Series the equipment. We recommend you consult your authorized Jacuzzi dealer for guidance before attempting to restart your spa under these conditions. 13.0 Water Quality Maintenance To decrease the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/or respiratory ailments, maintain water quality within specified limits. This will enhance your enjoyment and prolong the life of the hot tub’s equipment.
J-300 Series J-300 Series 13.2 Sanitizing To destroy bacteria and organic compounds in the spa water, a sanitizer must be used regularly. Chlorine and bromine are the two most popular sanitizers used to date. The “Proclear Mineral Spa Clarifier” designed especially for your hot tub is a beneficial product for water maintenance. Many other additives are available for your spa.
J-300 Series 14.0 Error Conditions/Error Messages Your spa has a self-diagnostic control system. The system will automatically display the following if a problem is detected. 14.1 Summer Logic When the actual spa water temperature reaches 2°F (1°C) above the set temperature, the spa goes into “summer logic.” The 24-hour circulation pump will turn off automatically to avoid adding additional heat to the water, eventually creating an overheat condition. This setting is not user-programmable.
J-300 Series J-300 Series 14.6 Panel Flashes FL1 or FL2 A flashing “FL1” display means the flow switch is malfunctioning open, the filter cartridge is excessively dirty or an “air lock” condition has occurred at the circulation pump intake. A flashing “FL2” display means the flow switch is malfunctioning closed. In either case, the spa heater will deactivate and jets pump #1 may also deactivate. To correct condition perform the following: 1. Verify water level is above all jets but below lowest pillow.
J-300 Series 15.0 Troubleshooting Procedures In the event your Jacuzzi spa is not working the way it should, please first review all the installation and operating instructions in this manual and check for messages on the panel display. If you are still not satisfied it is working properly, please follow the appropriate troubleshooting instructions below. Note: If any of the supply cords to accessories are damaged, they must be replaced by authorized service personnel.
J-300 Series J-300 Series 15.5 No Heat 1. Check thermostat setting. 2. Keep the spa cover in place while heating. 3. Check the settings to see if your spa is in economy filtration/heating mode (page 28). Should checking the above steps fail to correct the problem, please call your Jacuzzi Hot Tub dealer so that they may arrange service. We build the best spas in the industry. Nonetheless, we are always striving to improve the quality and features of our products.
42 PUMP 2 PUMP 1 HI HI LO CIRC. PUMP O3 C OZONATOR (OPTIONAL) BLK WHT RED BLK WHT BLK WHT BLK WHT GRN 1 K6 K5 K4 K3 K2 K1 2 RED W J7 7 BLK K7 J8 6 K8 Heater 5.5 kW 240 VAC This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any inteference received including interference that may cause undesired operation.
2 3 TB1 GRN WHT BLK RED 1 RED* BLK 4. If hot tub is to be operated on 30A service, make sure the jumper provided at location JP1 #1&2 on the circuit board is installed. If hot tub is to be operated on 40A service, remove the jumper JP1 #1&2 on the circuit board. 3. Permanently connect to the power supply. Use copper conductors ONLY. Wire size must be appropriate per NEC and/or local codes. 2. Move RED* wire from TB1 position #1 to TB1 position #3 as shown below. 1.
44 PUMP 2 PUMP 1 HI HI LO CIRC. PUMP O3 OZONATOR (optional) C BRN BLU BLK BRN BLU BRN BLU BRN BLU GRN 1 TB1 BLU J6 J19 J18 J17 J16 J15 J14 J13 J12 J11 J21 J20 2 BLU W J7 7 J8 6 BRN K7 K8 Heater 2.
O3 1 J6 J13 2 LO F1 K4 K3 K2 K1 Main Pump J5 J17 HI BLK K5 K7 BRN J8 K8 J1 J3 J2 Control Panel J9 BRN J10 Heater OUT BLU 7 5 3 1 JP1 8 6 4 2 Heater IN J7 BLU J4 W Temperature Sensor J-315/J-325 Waterfall Light/ Footwell Light Controller W X Heater Specifications • Export 50 Hz Model: 2.7 kW @ 230 VAC Temp.
J-300 Series 17.0 Optional Stereo Receiver Functions 1 8 9 2 10 3 11 4 12 13 5 14 6 15 7 16 17 J-335/J-345/J-355/J-365/J-375 Models Only: To start enjoying your optional stereo receiver, please read the following operation instructions in their entirely. 1. Power Button: Press PWR (Power) to turn deck on or off. 2. Equalization Button: Repeatedly press EQ/LD to choose from DSP Off, Jazz, Pop, Classic, Rock or Vocal equalization options.
J-300 Series J-300 Series 6. DISP Button: Press DISP to switch between clock and station frequency. When selected, the clock will display for 5 seconds then automatically revert back to station frequency. 7. Source Button: Press Source to change input from audio or CD mode to auxiliary mode. Press a second time to switch back. Note: Auxiliary mode (AUX) enables the external MP3 player mode. See section 17.1, page 53 for details. 8.
J-300 Series 1 8 9 2 10 3 11 4 12 13 5 14 6 15 7 16 17 13. Preset 4/RDM Button: In tuner mode, any station can be stored as preset 4 by simply pressing and holding this button for several seconds. To recall the station preset, simply press and release this button. In CD mode press this button to randomly play song tracks. Press again to turn off this feature. 14.
J-300 Series J-300 Series 19. Eject Button (Not Illustrated): To eject CD, press OPEN and flipdown the front access panel, then press the Eject button located to the left of CD slot. 20. USA/Europe Switch (Not Illustrated): You can switch between American (USA) and European radio frequency bands by flipping a switch located on the bottom of the deck. To change bands: • Power down unit • Lift up sticker under the CD player. • Choose desired frequency band as indicated on the sticker.
J-300 Series been recorded on an MP3 disc, NO FOLD, NO TRK, NO TLT, NO ALBM, NO ART will display. 24. Playback Order of The MP3 File: • A directory that does not include an MP3 file is skipped. • We recommend that you make no more than two levels for each disc. • Maximum number of folders: 256 • Maximum number of folder levels: 8 • Maximum number of characters for MP3 file name and folder name: 32 • Sampling frequency: 16 kHz, 22.05 kHz, 24 kHz, 32 kHz, 44.
J-300 Series J-300 Series 26.
52 Level 1 Level 2 Level 3 Level 4 Level 5 Example of a disc's folder/file hierarchy Folder File to return 10 files behind. to go 10 files forward.
J-300 Series J-300 Series 17.1 Audio System Remote Control Functions A remote control is supplied on all spas with the optional stereo system. This remote provides control over some of the radio and CD playback functions. P/S M F B/S External MP3 Playback The supplied remote control provides no control over external MP3 player operation of any kind with the exception of volume control and source selection. All External MP3 playback operations are performed solely by the MP3 player.
J-300 Series 17.2 External MP3 Player Connection Connecting An External MP3 Player (Purchased Separately) Any battery powered MP3 player can be connected to your new spa stereo system to enhance and personalize your spa experience! Connection Procedure 1. Connect MP3 Player to the auxiliary port located inside stereo enclosure using the supplied Mini RCA cable as shown. 2.
J-300 Series J-300 Series 17.3 Wireless Remote Battery Replacement Procedure 1. Turn the remote unit over and locate the battery door (Figure A). Fig. A CLOSED OPEN 2. Rotate the battery door, with a coin, counterclockwise until the dot aligns with the Open arrow (Figure B). Battery Door CLOSED OPEN Fig. B 3. Remove battery door using coin to pry the door upward (Figure C). CLOSED OPEN Fig. C 4. Replace battery using CR2430 or equivalent (Figure D). CLOSED OPEN LITHIUM BATTERY CR2430 3V Fig.
J-300 Series 56