Installation Guide

Jacuzzi
®
Comfort Pure Air™ II Bath: Installation and Operation Page 13 BM62000D • February 2008
ENGLISH
SERVICE ACCESS REQUIRED
FRONT
ALTERNATE
ACCESS
Blower
PREFERRED
ACCESS
18”
12”
18”
12”
Anchor strap
Floor
Nail or screw
through anchor
strap into oor
ANCHOR STRAP
ANCHOR STRAP
Drop-In Bath units are equipped with metal anchor straps.
These straps can be used to secure the unit to the oor or
sub-oor to reduce movement after installation. If mortar
or similar anchoring material is used, these straps are not
necessary.
WARNING: ALL foam feet must contact the oor. Anchoring
straps and/or other anchoring materials will not properly
anchor unit if ALL foam feet are NOT in contact with a level
oor. Operating a unit improperly installed may cause
irreparable damage to the unit.
SERVICE ACCESS
For partially or fully sunken installations, allow for access
to service connections. It is the installer’s responsibility
to provide sufcient service access. The recommended
minimum dimensions allowable for service to the bath are
shown in the “Service Access” illustration below.
Provide adequate ventilation for cooling and to supply
sufcient air for the blower. Do not insulate this area or
around blower.
SERVICE ACCESS (Non-skirted corner bath)
FRONT
Right-hand unit shown
A = Preferred access
B = Acceptable alternative if Access A is not possible
NOTE: Left hand unit access is on the opposite side (mirror image)
18”
24”
20”