SUMMER RAIN™ 2 WALL & 3 WALL WALK-IN SHOWER SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS
IMPORTANT SAFETY INFORMATION Do not place or use electrically connected devices, such as television, radio, or stereo speakers, lights, hair dryers, or telephones, within 1.5 m (5 feet) of shower. Note: This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath products.
CONTENTS 2 WALL Specifications _________________________________________________________________________ 2 Rough-in Reference ____________________________________________________________________ 3 Component Identification ________________________________________________________________ 4 Base Installation _______________________________________________________________________ 5-7 Tower and Glass Panels Installation ________________________________________________________ 8-12 3 WALL Specifications _________
2 WALL SPECIFICATIONS Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware. Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Immediately upon receipt, inspect the base and other components before installing. Check all carton inserts for parts and hardware.
2 WALL ROUGH-IN REFERENCE 84" FRONT VIEW 60" 33-3/4" 1-1/2" TILE FLANGE 23" 21-1/2" 1/2" RIGID COPPER PIPE UNDER BASE 27-15/16" 42-5/16" COLD SUPPLY HOT SUPPLY MINIMUM WATER PRESSURE FOR THE SYSTEM IS 40PSI TOP VIEW 3
2 WALL COMPONENT IDENTIFICATION STRAIGHT GLASS MOUNTING WALL POST MOUNTING CAP (2) POST TOWER WITH PLUMBING, FIXTURES, MAGNETIC GASKET, BOTTOM PLATE AND TOP COVER (PREASSEMBLED) HEX WRENCH (1) (PROVIDED) WALL MOUNT BRACKET (2) TOWER SUPPORT RAIL BRACKET COVER (2) GLASS PANEL SUPPORT RAIL CURVED GLASS WALL MOUNTING POST FRONT RAIL GLAZING GASKET TAPE (6 PIECES) 3 SCREWS AND 3 WALL ANCHORS PER MOUNTING POST GLAZING GASKET (3) CURVED GLASS STRAIGHT GLASS PANEL BOTTOM BRACKET CORNER POST GLAZING GA
2 WALL BASE INSTALLATION PRELIMINARY ROUGH-IN INSTALLATION INSTRUCTIONS The floor structure beneath the unit must be able to support a total weight of the unit and bather. Refer to the table under total weight. STEP 2 Remove the stainless steel strainer from the drain assembly. Disassemble the locknut and two gaskets from the back of the drain assembly. Apply a 1/4" bead of caulking (silicone) to the drain hole and insert the drain assembly.
2 WALL BASE INSTALLATION STEP 4 With the drain fitting passing over the center of the drainpipe, lower the shower base carefully into place, push down firmly until the base is in place. You must check the level of the base in two directions. Do not lift a corner to level the base. This will cause a loss of contact with the mortar. Attach the shower base flange to the stud wall and blocking with self-drilling screws (included). Use a minimum of 3 screws per flange section.
2 WALL BASE INSTALLATION STEP 6 STEP 8 Place cement board or equivalent on top of shower base flange and secure to studwall. Filling the area marked DO NOT FILL will prevent moisture from draining back into the base through the weep holes. This moisture is due to leakage through the tile grout. Sealing the tile grout will prevent this leakage.
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 3A Slide straight glass panel all the way into wall post. Mark position of glass post. Remove panel. STEP 1 Position the wall posts so the edge of the post is set back 3/4" (19 mm) in from the edge of the base 3/4" (19 mm) FINISH WALL EDGE OF BASE STEP 2 Level both wall posts in their proper position and mark where screw holes are to be drilled. Drill 3/16" holes and secure with wall anchors and screws provided.
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 4 Slide the glass panel into the wall post. Make sure that the corner notch is positioned toward the base of the tower. STEP 6 Insert tower support rail into glass panel rail but do not tighten at this time. GLASS PANEL SUPPORT RAIL TOWER SUPPORT RAIL STEP 7 Insert support rails into brackets in top moulding of tower but do not tighten at this time. Front and tower support rails may have to be cut if they are too long.
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 9 Place the front rail and tower support rail against the walls. Check level and mark the position for the rail mounting bracket. The screw position will be above the rail. Drill the wall with a 3/16" bit and secure bracket with screws and wall anchors provided. STEP 11 Secure the rails. ATTACH RAIL BRACKET TO WALL SECURE RAIL TO BRACKET (TURN CW TO TIGHTEN) STEP 12 Tighten the tower base bolt. Two shut-off valves are provided.
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 14 Install cover cap on fixed glass wall post. STEP 13A Insert fixed glass support rail into panel post and tighten set screw. COVER CAP STEP 13B Drill a 1/8" pilot hole into tower support rail using the hole in the glass panel support rail. Screw M3.5X9.5 mm screw into hole. STEP 15 Install glazing gasket on fixed glass wall post and curved glass wall post on the inside. Note orientation of gasket.
2 WALL: TOWER, FIXED WALL AND CURVED GLASS INSTALLATION STEP 16 Turn on water supply and check for leaks. Correct any leaks before installing tower cover. STEP 18 Seal all around the base of tower with silicone sealant. Also seal the inside of both wall posts, glass post and the bottom of both glass panels on the inside only. STEP 17 Install tower cover as shown. Insert cover at top first.
3 WALL SPECIFICATIONS Important: Read complete instructions before beginning installation. Each unit arrives ready for installation, equipped with base, glass and associated hardware. Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Immediately upon receipt, inspect the base and other components before installing. Check all carton inserts for parts and hardware.
3 WALL ROUGH-IN REFERENCE 84" FRONT VIEW 60" 33-3/4" 1-1/2" TILE FLANGE 23" 21-1/2" 1/2" RIGID COPPER PIPE UNDER BASE 27-15/16" 42-5/16" COLD SUPPLY HOT SUPPLY MINIMUM WATER PRESSURE FOR THE SYSTEM IS 40PSI TOP VIEW 14
3 WALL COMPONENT IDENTIFICATION TOWER WITH PLUMBING, FIXTURES, MAGNETIC GASKET, BOTTOM PLATE AND TOP COVER (PREASSEMBLED) HEX WRENCH (1) (PROVIDED) WALL MOUNT BRACKET (2) CURVED GLASS WALL MOUNTING POST TOWER SUPPORT RAIL MOUNTING POST CAP FRONT RAIL BRACKET COVER (2) TAPE (3 PLACES) GLAZING GASKET CURVED GLASS TOWER COVER GLAZING GASKET (2) TOWER MOUNTING BOLT & WASHER SELF DRILLING SCREW BASE 15 3 SCREWS AND 3 WALL ANCHORS
3 WALL BASE INSTALLATION PRELIMINARY ROUGH-IN INSTALLATION INSTRUCTIONS The floor structure beneath the unit must be able to support a total weight of the unit and bather. Refer to the table under total weight. STEP 1 Provide an opening in the subfloor no less than 5" x 5" square. This opening should be located on the center lines of the shower base drain hole (See Product Chart). The opening is to accommodate a 2" waste pipe. The waste pipe should be 1/4" to 1/2" above the surface of the subfloor.
3 WALL BASE INSTALLATION STEP 4 With the drain fitting passing over the center of the drainpipe, lower the shower base carefully into place, push down firmly until the base is in place. You must check the level of the base in two directions. Do not lift a corner to level the base. This will cause a loss of contact with the mortar. Attach the shower base flange to the stud wall and blocking with self-drilling screws (included). Use a minimum of 3 screws per flange section.
3 WALL BASE INSTALLATION STEP 6 With the drain fitting passing over the center of the drainpipe, lower the shower base carefully into place, push down firmly until the base is in place. You must check the level of the base in two directions. Do not lift a corner to level the base. This will cause a loss of contact with the mortar. Attach the shower base flange to the stud wall and blocking with self-drilling screws (included). Use a minimum of 3 screws per flange section.
3 WALL: TOWER AND CURVED GLASS INSTALLATION STEP 3 Slide the glass panel into the wall post. Make sure that the corner notch is positioned toward the base of the tower. STEP 1 Position the wall post so the edge of the post is set back 3/4" (19 mm) in from the finish wall. FINISH WALL 3/4" (19 mm) STEP 2 Level the post in its proper position and mark where screw holes are to be drilled. Drill 3/16" holes and secure with wall anchors and screws provided.
3 WALL: TOWER AND CURVED GLASS INSTALLATION STEP 7 Place the front rail and tower support rail against the walls. Check level and mark the position for the rail mounting bracket. The screw position will be above the rail. Drill the wall with a 3/16" bit and secure bracket with screws and wall anchors provided. STEP 5 Insert support rails into brackets in top moulding of tower but do not tighten at this time.
3 WALL: TOWER AND CURVED GLASS INSTALLATION STEP 9 Secure the rails. STEP 11 Install cover cap on wall post. COVER CAP STEP 10 Tighten the tower base bolt. Two shut-off valves are provided. To hook up supply lines, unscrew valves from braided line. Using thread sealant, screw valve to stub outs at bottom of tower. Then reconnect braided line using provided gasket. Do not twist or kink supply lines when connecting. STEP 12 Install glazing gasket on curved glass wall post on the inside.
3 WALL: TOWER AND CURVED GLASS INSTALLATION STEP 13 Turn on water supply and check for leaks. Correct any leaks before installing tower cover. STEP 15 Seal all around the base of tower with silicone sealant. Also seal the inside of both wall posts, bottom of both glass panels on the inside only. STEP 14 Install tower cover as shown. Insert cover at top first.
2 & 3 WALL OPERATION Shower Head There are four selectable positions: Jet, normal pulsating and aerated flow. Body Sprays (2 Upper & 2 Lower) To adjust the flow and intensity, turn as shown. The spray can also be turned to change the direction of the spray. LESS FLOW AND INTENSITY MORE FLOW AND INTENSITY STOP RELEASE Diverter Control To turn On water, turn the inner knob clockwise and adjust for more or less flow.
2 & 3 WALL MAINTENANCE To remove any lime scale from the shower head and body sprays , rub with your finger the outer ring of nozzles on the shower head and all nozzles on the body spray. To clean the foot temperature tester, unscrew the nozzle and back flush the wire mesh filter. Do not use metal tools (such as scissors or screwdrivers, etc.) to clean the body sprays, shower head or foot temperature tester. To cleanthe base, simply use a mild, nonabrasive liquid detergent solution.
TOWER FIXTURES REPAIR PARTS 1 (5X) 2 (5X) 3 (5X) TOWER ASSEMBLY 4 9 (5X) 6 10 5 11 (4X) 7 (Part of U547000) 8 12 13 14 15 16 17 18 PART OF D709827 WASHER (PART OF D709827) 19 1. C546000 Lock Nut, 1/2" NPT WP (5X) 2. G559000 Ring Compression SS (5X) 3. G560000 Washer Rubber (5X) 4. U546000 (Part of U547000) Nut Transfer Valve, Chrome 5. U566000 Gasket, 1.41 ID X .063 Thick 6. U547000 Valve, Mixer/Transfer Assembly 7. U550827 (Part of U547000) 567000Nut, Mixer Valve, Chrome 8. U567000 Gasket, 1.
TOWER PLUMBING REPAIR PARTS 1. A944000 (9X) Spring Clamp, .625 OD Hose 2. U405000 L=31.0" Tubing, PVC Reinforced, 10mm Barb 3. U405000 L=5.5" Tubing, PVC Reinforced, 10mm Barb 4. A945000 (7X) Spring Clip, .75 OD Hose 5. U400000 FTG, Straight, 1/2" FTS X 10mm Barb 6. U403000 (2X) Cap, 1/2" FST 7. U711000 (2X) Strainer Washer, 1/2" Dia. 8. U405000 L=31.0" Tubing, PVC Reinforced, 10mm Barb 9. U540000 (2X) 1/2" Flexhose 38", Female Swivel Heads 10. GASKET (2X) Gaskets Supplied with Hose 11.
2 WALL UNIT REPAIR PARTS 5 (2X) 6 (2X) 4 1 3 7 (6X) 2 8 11 12 9 10 14 (6X) 13 (6X) 17 18 15 U134827 Rail Back Walk-in 16 U133827 Rail 2 Wall Walk-in U245827 Rail Assembly Walk-in U149000 Bracket, Mounting Rail U119827 Wall Post, Panel U138827 Cap, Wall Post J686000 Tape High Bond, 2 Sided U159000 Gasket,Vinyl, Glass Panel U479XXX Glass Panel Assembly, Walk-in U124XXX Tower Cover U257XXX Final Shell, Tower Walk-in U126XXX Tower Body Walk-in U136XXX Cap, Top, Tower U137XXX Cap, Bottom, Tower U149000 Bra
3 WALL UNIT REPAIR PARTS 5 1 2 3 (2X) 4 10 7 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 8 (2X) 9 U134827 Rail Back Walk-in 3 Wall 6 U245827 Rail Assembly Walk-in 3 Wall U149000 Bracket, Mounting Rail U119827 Wall Post, Panel U138827 Cap, Wall Post U124XXX Tower Cover U257XXX Final Shell, Tower, Walk-in 3-Wall U126XXX Tower Body Walk-in U136XXX Cap, Top Tower U137XXX Cap, Bottom, Tower U149000 Bracket, Mounting Rail U354000 Screw, Self Tap,#8-1.25" L U355000 Screw, Self Tap,#8-2.
Jacuzzi Whirlpool Bath Limited Warranty Designer Collection Shower Product WARRANTY COVERAGE Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Designer Collection Bath Product (“unit”) who purchases the product for personal or single family use (“user”). The Company will repair or replace, at its option, the unit or its equipment in accordance with the following terms and conditions.
RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility. In the event of a problem, the unit must not be installed.