User's Guide
Table Of Contents
- THINGMAGIC M6e User Guide
- Introduction
- Hardware Overview
- Hardware Interfaces
- Digital/Power Connector
- USB Interface
- General Purpose Input/Output (GPIO)
- Power Requirements
- Special RF Power Output Requirements for the M6e-A
- Environmental Specifications
- Electro-Static Discharge (ESD) Specification
- Mounting Screw Clearance
- Assembly Information
- Antennas
- M6e Mechanical Drawing
- Authorized Antennas
- M6e-A Authorized Cables
- Firmware Overview
- New Features - Version 1.21.2
- Margin Read Support for Monza6 Tags
- NXP UCODE7 Configuration Support
- Gen2 Parameters in Metadata
- Support for Acura Gen2V2 Tags
- Support for GEN2V2 Embedded Tag Ops
- Gen2V2 Support
- Denatran Tag Support
- Configurable T4 for Gen2 Protocol
- Ability to “Read Data” Immediately After Sending a “Write EPC” or “Write Data” Command
- Decoupling Antenna Selection from AsyncOnTime
- Support for Additional Regions
- Support for Set/get Quantization Value and Minimum Frequency in Open Region
- Operational Notes
- Boot Loader
- Application Firmware
- Custom On-Reader Applications
- New Features - Version 1.21.2
- Communication Protocol
- Functionality
- Specifications
- Compliance and IP Notices
- Error Messages
- Getting Started – Development Kit and Carrier Board
- Environmental Considerations
ThingMagic M6e User Guide 53
www.JADAKtech.com
FAULT_PROTOCOL_INV
ALID_WRITE_DATA
408h An ID write was attempted
with an unsupported/incorrect
ID length.
Verify the Tag ID length being
written.
FAULT_PROTOCOL_INV
ALID_ADDRESS
409h A command was received
attempting to access an
invalid address in the tag data
address space.
Make sure that the address
specified is within the scope of the
tag data address space and
available for the specific
operation. The protocol
specifications contain information
about the supported addresses.
FAULT_GENERAL_TAG_
ERROR
40Ah This error is used by the
GEN2 module. This fault can
occur if the read, write, lock, or
kill command fails. This error
can be internal or functional.
Make a note of the operations you
were performing and contact rfid-
support@jadaktech.com.
FAULT_DATA_TOO_LAR
GE
40Bh A command was received to
Read Tag Data with a data
value larger than expected or
it is not the correct size.
Check the size of the data value in
the message sent to the reader.
FAULT_PROTOCOL_INV
ALID_KILL_PASSWORD
40Ch An incorrect kill password was
received as part of the Kill
command.
Check the password.
FAULT_PROTOCOL_KILL
_FAILED
40Eh Attempt to kill a tag failed for
an unknown reason.
Check tag is in RF field and the kill
password.
FAULT_PROTOCOL_BIT_
DECODING_FAILED
40Fh Attempt to operate on a tag
with an EPC length greater
than the Maximum EPC length
setting.
Check the EPC length being
written.
FAULT_PROTOCOL_INV
ALID_EPC
410h This error is used by the
GEN2 module indicating an
invalid EPC value has been
specified for an operation.
This fault can occur if the
read, write, lock, or kill
command fails.
Check the EPC value that is being
passed in the command resulting
in this error.
FAULT_PROTOCOL_INV
ALID_NUM_DATA
411h This error is used by the
GEN2 module indicating
invalid data has been
specified for an operation.
This fault can occur if the
read, write, lock, or kill
command fails.
Check the data that is being
passed in the command resulting
in this error.
Protocol Fault Errors (Continued)
Message Code Cause Solution