User's Guide
Table Of Contents
- COPYRIGHT INFORMATION
- TECHNICAL SUPPORT AND CONTACT INFORMATION
- Introduction
- Hardware Overview
- SMT Reflow Profile
- Host Board Design
- ThingMagic M3e Carrier Board
- TBD
- Programming for ThingMagic M3e
- Upgrading the ThingMagic M3e
- Verifying Application Firmware Image
- Host-to-Reader Communication
- Reader-to-Host Communication
- CCITT CRC-16 Calculation
- Power Modes
- Federal Communication Commission (FCC) Interference Statement
- User Manual Requirement
- End Product Labeling
- End Product Labeling
- Authorized Antennas
- Antennas
- Antennas
- Both the HF antenna and the LF antenna are attached to the Carrier Board.
- The HF antenna is embedded in the PCB of the Carrier Board.
- The LF antenna is connected to the Carrier Board.
- Powering Up and Connecting to a PC
- USB/RS232
- ESD Damage Overview
- Identifying ESD as the Cause of Damaged Readers
- Common Installation Best Practices
- Environmental
ThingMagic M3e User Guide
12
www.JADAKtech.com
On power up, ThingMagic M3e module configures its GPIOs as inputs to avoid contention from user
equipment that may be driving those lines. The input configuration is a 3.3-volt logic CMOS input and is
internally pulled down with a resistance value of between 20 and 60 kΩ (40 kΩ nominal).
Lines configured as inputs must be low whenever the module is turned off and low at the time the
module is turned on.
GPIOs may be reconfigured individually after power up to become outputs. Lines configured as outputs
consume no excess power if the output is left open.
Configuring GPIO Settings
The GPIO lines are configured as inputs or outputs through the MercuryAPI by setting the reader
configuration parameters /reader/gpio/inputList and /reader/gpio/outputList. The state of the lines can be
Get or Set using the gpioGet() and gpioSet() methods, respectively. See the programming language-
specific reference document included with the Mercury API.
Run Line
The run line turns off the power supplies.
Pull down to turn off the power supplies.
Leave open to operate.
This line is pulled up to module Vin through a 1 M Ohm resistor
Turn off time = TBD
Turn on time = 22 ms
DC Power Requirements
Voltage: 3.0 - 5.5 VDC
Current: 0.3 A typical at 5.0 V when reading; idle and sleep modes supported.