Installation Guide
1/4 in. gap
lower
panel
Z-flashing
upper panel
Do not
Caulk
HardieTrim 
Batten
1/4 in. gap
Z-flashing
upper panel
Do not
Caulk
HardieTrim
Batten
HardieTrim
Batten
lower
panel
Figure 17
Figure 18
Visit jameshardiepros.com for the most recent version.
TR1510_P5/9 09/19
HardieTrim
®
 Boards
HORIZONTAL PANEL JOINTS
At horizontal panel joints HardieTrim battens must be 
installed according to option 1 or 2 below. When 
installing HardieTrim Battens horizontally, they must be 
installed as a panel joint according to option 2. 
Option 1
Figure 17 - No horizontal band board - Make a 22.5 - 45 
degree weather cut, in the HardieTrim batten, just above 
the 1/4 in. clearance between panels. 
Option 2
Figure 18 - Horizontal Band Board - Install a horizontal 
band board at the top of the bottom panel. Butt the lower 
batten to the band board and start the top batten at the 
bottom edge of the top panel. Maintain a 1/4 in. 
clearance above horizontal flashing.
BATTEN BOARDS