Installation Guide

103
HS11121_P5/5 6/13
PRIMING & PAINTING
DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie
®
Products.
James Hardie
®
products must be painted within 180 days for primed product and 90
days for unprimed. In addition non ColorPlus
®
product versions of HardieShingle
®
Siding
require a field applied prime coat. 100% acrylic primers and topcoats are
recommended. Do not paint when wet. For application rates refer to paint
manufacturers specifications. Back rolling is recommended when paint is spray applied.
PAINTING JAMES HARDIE
®
SIDING AND TRIM PRODUCTS WITH COLORPLUS
®
TECHNOLOGY
When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application:
• Ensure the surface is clean, dry, and free of any dust, dirt, or mildew
• Repriming is normally not necessary
• 100% acrylic topcoats are recommended
• DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie
®
Products.
• Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature
• DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section
Consult applicable code compliance report for correct fasteners type and
placement to achieve specified design wind loads.
NOTE: Published wind loads may not be applicable to all areas where
Local Building Codes have specific jurisdiction. Consult James Hardie
Technical Services if you are unsure of applicable compliance documentation.
Drive fasteners perpendicular to siding and framing.
Fastener heads should fit snug against siding (no air space). (fig. A )
Do not over-drive nail heads or drive nails at an angle.
If nail is countersunk, fill nail hole and add a nail. (fig. B)
For wood framing, under driven nails should be hit flush to the plank with a
hammer (For steel framing, remove and replace nail).
Do not use aluminum fasteners, staples, or clipped head nails.
PNEUMATIC FASTENING
GENERAL FASTENING REQUIREMENTS
James Hardie products can be hand nailed or fastened with a pneumatic tool.
Pneumatic fastening is highly recommended. Set air pressure so that the
fastener is driven snug with the surface of the siding. A flush mount
attachment on the pneumatic tool is recommended. This will help control the
depth the nail is driven. If setting the nail depth proves difficult, choose a
setting that under drives the nail. (Drive under driven nails snug with a
smooth faced hammer - Does not apply for installation to steel framing).
COLORPLUS
®
TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE
WINDOWS AND DOORS
Building wall components such as windows, doors and other exterior wall penetrations shall be installed in accordance with the component manufacturer’s written
installation instructions and local building codes. Where windows or doors are installed, continue the application of siding as if the wall is complete. Triming for the
opening and using the resulting piece may throw off the spacing above the break.
Figure 21
CORNER DETAILS
A. Panels butted against corner boards.
B. Panels butted against square wood
strip on inside corner, flashing behind.
C. Laced outside corner.
D. Laced inside corner.
minimum (1") thick trim
CAULKING
For best results use an Elastomeric Joint Sealant complying with ASTM C920
Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM
C834. Caulking/Sealant must be applied in accordance with the
caulking/sealant manufacturer’s written instructions. Note: OSI Quad as well
as some other caulking manufactuers DO NOT allow tooling.
Figure A Figure B
countersunk,
fill & add nail
snug flush
DO NOT
under drive nails
DO NOT
staple
CUT EDGE TREATMENT
Caulk, paint or prime all field cut edges. James Hardie touch-up kits are
required to touch-up ColorPlus products.
Fasteners must be corrosion resistant, galvanized, or stainless steel.
Electro-galvanized are acceptable but may exhibit premature corrosion.
James Hardie recommends the use of quality, hot-dipped galvanized nails.
James Hardie is not responsible for the corrosion resistance of fasteners.
Stainless steel fasteners are recommended when installing James Hardie
®
products near the ocean, large bodies of water, or in very humid climates.
• Care should be taken when handling and cutting James Hardie ColorPlus products. During installation use a wet soft cloth or soft brush to gently wipe off any
residue or construction dust left on the product, then rinse with a garden hose.
• Touch up nicks, scrapes and nail heads using the ColorPlus
®
Technology touch up applicator. Touch-up should be used sparingly. If large areas require
touch-up, replace the damaged area with new HardieShingle
®
siding with ColorPlus Technology.
• Laminate sheet must be removed immediately after installation of each course.
• Terminate non-factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus
®
product dealer.
• Treat all other non-factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer.
Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up, will not
be covered under the James Hardie ColorPlus Limited Finish Warranty.
RECOGNITION: In accordance with ICC-ES Evaluation Report ESR-2290, HardieShingle lap siding is recognized as a suitable alternate to that specified in: the 2006,2009,&2012 International Residential Code
for One- and Two-Family Dwellings, and the 2006, 2009, & 2012 International Building Code,. HardieShingle lap siding is also recognized for application in the following: City of Los Angeles Research Report No.
24862, State of Florida listing FL#889, Dade County, Florida NOA No. 02-0729.02, U.S. Dept. of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA
223-93-M, and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications
Please visit www.jameshardie.com for Additional
Product Information and Availability,
Installation Information, Warnings, and Warranties
© 2013 James Hardie Building Products, Inc. All rights reserved.
TM, SM, and ® denote trademarks or registered trademarks of
James Hardie Technology Limited. is a registered
trademark of James Hardie Technology Limited.