Use and Care Manual

7/16” OD Rod
Since 1956
OPERATION AND SAFETY MANUAL
Trace Underground Pipe Without Digging
- Less Disruption To Roads And Landscapes
- Minimal Pavement Breakage, Excavation, Restoration
Connect a signal transmitter to the Duct Hunter™ to energize unit
with a specic frequency. When rod is pushed into underground
pipe, signal radiates outward where a receiver detects frequen-
cy, allowing utility pipe to be traced from above ground.
• Trace to depths up to 10’
• Locate sewer laterals to conrm no cross bore has occurred
• Locate ductile iron, plastic, tile or concrete pipe
• Rod marked in 5’ increments
• 9” Bend radius
Jacket Core Wire
Warranty
Jameson products carry a warranty against any defect in material and workmanship for a period of one year from date
of shipment unless failure is due to misuse or improper application. Jameson shall in no event be responsible or liable for
modications, alterations, misapplications or repairs made to its products by purchaser or others. This warranty is limited
to repair or replacement of the product and does not include reimbursement for shipping or other expenses incurred.
Jameson disclaims any other express or implied warranty.
Duct Hunter
Rod
Diameter
Rod
Length
Recommended
Conduit Size
13-716-400M 7/16” 400’ 4” or Larger
13-716-500M 7/16” 500’ 4” or Larger
13-716-600M 7/16” 600’ 4” or Larger
13-716-800M 7/16” 800’ 4” or Larger
13-716-1000M 7/16” 1000’ 4” or Larger
• Wear safety glasses and gloves.
• Keep rod inside reel when not in use. Out-of-control rod can harm personnel or property.
• Keep rod clean. Some contaminants (including water) can conduct electricity.
• Keep secure footing. Protect yourself from falling should pulling eye move suddenly or separate from rod.
• Check for rod damage prior to use. Cracks, gouges, nicks, or white stress marks on jacket or sharp bends will weaken rod.
Injury could result if rod breaks while pulling.
• Do not use slip joint pliers, locking pliers or powered pulling equipment on rod.
• Do not force a pull that is stuck. Check for kinks or obstructions.
• Avoid pulling rod over sharp edges.
• Do not bend rod beyond 9” radius.
Do not use on live circuits. Electric shock may result. The Duct Hunter is equipped with a metal tip and
continuous internal copper wire. Do not use on or near live circuits. Electric shock may occur.
WARNING - ADHESIVE
Read manufacturer’s instructions before using adhesive. In case of eye contact, ush with water and seek medical atten-
tion If skin contact occurs, apply solvent (such as nail polish remover) to area and gently remove adhesive. Wash solvent
off with water. Solvents should not be used in case of contact with eyes or open wounds.
Always wear safety goggles (ANSI Std. Z87.1) and gloves when working with adhesive and/or unprotected berglass rod.
See adhesive product label for Safety Data Sheet (SDS).
Rod Is Marked In 5’ Increments
Add “MM” To Part Number For Metric Marked Rod
Add AWK To Part Number For All-Terrain Wheels