Operation Data Owner's Manual OneTouchTM Control Systems Sheet #6593, Rev. J For use with Pool/Spa Combination, Pool Only/Spa Only, and Dual Equipment AquaLink® RS Systems. WARNING FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/ spa service technician. The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death.
Page Table of Contents NOTE Some of the features described in this Manual DO NOT apply to all AquaLink® RS models. Section 1. Important Safety Instructions............ 5 Section 7. Using the System Setup Menu.......... 23 Section 2. Overview of the OneTouch™ Control Panel..................................... 7 OneTouch Menu................................ 23 Label Auxiliary Menu....................... 24 Boost Setup Menu............................. 24 Freeze Protection Menu....................
Page
Page Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS Lire la notice technique. All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: DANGER To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub.
Page WARNING People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning. Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub. Water temperature in excess of 100°F/38°C may be injurious to your health.
Page Section 2. Overview of the OneTouch™ Control Panel This document gives instructions for operating the Jandy AquaLink® RS OneTouch Indoor Control Panel. The instructions must be followed exactly. Read through the instructions completely before operating the equipment. 2.1 Basic Functions The AquaLink® RS OneTouch™ can turn your pool/spa equipment on and off in any of the following three ways: 1. Activate the equipment manually through the EQUIPMENT ON/OFF menu. 2.
Page Section 3. Using the Equipment On/Off Menu Equipment On/Off Use this menu to manually turn a piece of equipment on or off. The ALL OFF mode will turn off equipment that has been turned on by any means (manual or pre-programmed). This includes any of the heater enables that were on (unless in use by the Maintain function). To use Equipment On/Off 1. Highlight EQUIPMENT ON/OFF and press SELECT. To highlight an item, use the UP/DOWN arrow keys. Use the SELECT button to turn the equipment on or off.
Page Spa The SPA mode switches water circulation from the pool to spa (pool/spa combination models only). Turning on the spa also activates the filter pump (after a delay for valve rotation) and deactivates the pool cleaner if it is on. The SPA mode must be on to display the spa temperature and/or to heat the spa. Activation takes place after a thirty second delay (while valves are turning). To use Spa Highlight SPA and press SELECT. Use the SELECT button to turn the spa on or off.
Page 10 Spa Heat The SPA HEAT enables the heater for the spa. When the LED is green, the heater is enabled. When the LED is red, the heater is on and firing. It uses the settings from SET TEMP menu, or you can increase/decrease when enabling. To use Spa Heat Highlight SPA and press SELECT. The spa will come on after a short delay. Highlight SPA HEAT and press SELECT. Use the UP/DOWN arrow keys to set the desired temperature and press SELECT.
Page 11 Auxiliary Equipment The AUX modes control each of the auxiliary devices plus an extra AUX. To assign a different name to an auxiliary device, use the SYSTEM SETUP and LABEL AUX menus. To turn an Auxiliary on or off Highlight an AUX and press SELECT. Use the SELECT button to turn the equipment on or off.
Page 12 Chiller NOTE This equipment may not be part of your system. Please check with your installer. The CHILLER selection controls the chilling operation of the heat pump. In order to use the chiller, the filter pump must be turned on and the heat pump must be in CHILL MODE (see page 23, Using the System Setup Menu), and the switch on the heat pump on the equipment pad must also be set to CHILL MODE. NOTE CHILLER takes the place of EXTRA AUX or SOLAR HEAT.
Page 13 FILTER PUMP ON OFF SPA POOL HEAT OFF OFF SPA HEAT SOLAR HEAT OFF OFF AUX 1 LAMINAR PLSR ON OFF AUX 3 OFF AUX 4 OFF AUX 5 OFF AUX 6 OFF AUX 7 LAMINAR PULSE WILL TURN OFF IN 5 SECONDS. IF YOU WANT TO CHANGE SETTING PRESS SELECT NOW. LAMINAR LIGHT PULSE CONTROL OFF TIMED SLOW TIMED MED TIMED FAST RANDOM GROUP RANDOM SINGLE PATTERN SLOW PATTERN FAST PLEASE WAIT . . . CYCLING TO CHOSEN SETTING Set Light Colors NOTE This equipment may not be part of your system. Please check with your installer.
Page 14 Section 4. Using the Equipment On/Off Model Specific Menus TEMP1 (Pool or Spa Only) TEMP1 is the priority temperature. It must be set higher than TEMP2, and it overrides TEMP2 whenever it is enabled. Set temperature for TEMP1 before setting temperature for TEMP2. To set TEMP1 (Pool or Spa Only) Highlight TEMP1 and press SELECT twice. Use the UP/DOWN arrow keys to set the desired water temperature and press SELECT to make that degree setting take effect.
Page 15 Spa (Dual Equipment) Turning on the spa activates the filter pump. The SPA mode must be on to display the spa temperature and/or to heat the spa. To use Spa (Dual Equipment) Highlight SPA PUMP and press SELECT. Use the SELECT button to turn the spa on or off.
Page 16 Section 5. Using the OneTouch Menu OneTouch Each individual OneTouch mood/scene setting will allow you to run multiple devices and heat to preset water temperatures with the touch of one button (see OneTouch under System Setup menu). To use OneTouch Use this menu to turn on or off one of three mood/scene settings. Highlight ONETOUCH ON/OFF and press SELECT. To activate a mood/scene setting, use the button directly opposite to select the proper mode.
Page 17 Section 6. Using the Help Menu Keys Menu In the HELP menu you will find the KEYS menu. The KEYS menu identifies the buttons on the control panel. To use the Keys menu Highlight MENU/HELP and press SELECT, highlight HELP and press SELECT. Highlight KEYS by using the UP/DOWN arrow keys and pressing SELECT. Return to the main menu by highlighting CONTINUE and pressing SELECT or use the BACK button.
Page 18 Program Menu The Program menu allows on and off times for any equipment controlled by the AquaLink RS. You can program equipment to turn on or off all days, weekends, weekdays, or any specific day of the week. Each piece of equipment can be programmed for multiple on/off times each day. To add programs use the PROGRAM menu. Highlight ADD PROGRAM, and press SELECT. Use UP/DOWN arrows keys to set times, press SELECT to continue. To delete programs, use the PROGRAM menu.
Page 19 Set Temperature Menu The SET TEMP menu allows you to preset the pool and spa thermostats. The default pool temperature is 80°F. The default spa temperature is 102°F. (The default TEMP1 temperature is 80º F. The default TEMP2 temperature is 60º F.) SET TEMP will allow you to ENABLE the Maintain Temperature feature and adjust the hours to limit the time of day the Maintain Temperature feature will be active.
Page 20 Set Time Menu The SET TIME menu allows the correct time and date to be entered. The correct time and date ensures that programming will work properly. To set the Time Highlight MENU/HELP and press SELECT, highlight SET TIME and press SELECT. Use the UP/DOWN arrow keys to set values. Press the SELECT button to continue. MENU SET TIME HELP PROGRAM SET TEMP SET TIME DISPLAY LIGHT LOCKOUTS PROGRAM GROUP SYSTEM SETUP 03/01/00 WED 1:00 PM Use ARROW KEYS to set value.
Page 21 Lockout Menu The LOCKOUTS menu prevents changes to specific AquaLink RS operations. When SYSTEM feature is on "LOCK", changes to program and system setup items are prevented. When SPALINK RS and SPA SWITCH features are on "LOCK", all control from the SpaLink RS and Spa Side Switch are prevented. When DEVICE feature is on "LOCK", the selected device will not activate either manually or by programming.
Page 22 System Setup Menu Check with installer before making changes to the SYSTEM SETUP. To use the System Setup menu Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT. Use the UP/DOWN arrow keys to move the highlight bar up or down, or use PAGE UP or PAGE DOWN to move through the menus. Press SELECT on the highlighted item to move to the next screen.
Page 23 Section 7. Using the System Setup Menu OneTouch Menu This menu allows custom configuration of the three OneTouch mood/scene buttons. You can choose a predetermined name from the SELECT NAME menu or enter a CUSTOM NAME. You can also select specific devices for each mood/scene button. Each mood setting allows for an independent thermostat setting. OneTouch setting can also be assigned to any SpaLink button.
Page 24 Label Auxiliary Menu The LABEL AUX menu allows custom naming of auxiliary equipment. For example, you can set the display to read YARD LIGHT instead of AUX 4 . To use the Label Auxiliary menu Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight LABEL AUX, press SELECT. Highlight auxiliary to be labeled and press SELECT. Highlight either GENERAL LABELS, LIGHT LABELS, WTRFALL LABELS, or CUSTOM LABEL and press SELECT.
Page 25 Freeze Protection Menu Use Freeze Protection menu to assign freeze protection to your pool and spa equipment. When a piece of equipment is assigned to freeze protection, it will turn on when the AquaLink RS detects freezing conditions. The main filter pump is freeze-protected as a default. Activation temperature can be adjusted between 34° and 42° F. Default freeze protection activation temperature is 38º F and will deactivate within 2° F.
Page 26 Degrees C/F Menu The Degrees C/F menu allows you to change the AquaLink RS temperature display from Fahrenheit to Celsius or vice versa. When changing from Fahrenheit to Celsius you will have to re-enter the temperature settings. To change the Temp readout Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight DEGREES C/F and press SELECT. Use the UP/DOWN arrow keys to highlight desired setting and press SELECT.
Page 27 In Floor Cleaning Menu This menu is used to ENABLE or DISABLE the automatic in floor cleaning feature. When enabled the AquaLink RS rotates the in-floor Jandy Valve Actuators (JVAs) every 20 minutes. To use In Floor Cleaning menu Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight IN FLOOR CLEANING and press SELECT. This menu is used to ENABLE or DISABLE the in floor cleaning (rotates the JVAs every 20 minutes).
Page 28 SYSTEM SETUP PUMP LOCKOUT DURING VALVE SWITCHING FREEZE PROTECT AIR TEMP DEGREES C/F DAYLIGHT SAVIN TEMP CALIBRATE IN FLOOR CLEAN SOLAR PRIORITY PUMP LOCKOUT MORE ENABLED DISABLED Choose setting and Press SELECT Assign JVA Menu The ASSIGN JVAs menu allows Jandy Valve Actuators (JVAs) to be assigned to any auxiliary button. This means that whenever you press that auxiliary button, a valve turns.
Page 29 Spa Side Switch Menu The Spa Side Switch menu allows you to define which equipment is controlled by the buttons on the optional Spa Side Switch(es). Default settings are spa, spa heat, Aux1 and Aux2. You may want to write down your spa side switch button assignments so that you can label the buttons on the switch with the label pack provided. To set the Spa Side Switch Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight SPA SWITCH and press SELECT.
Page 30 SpaLink® Menu The SPALINK menu allows you to define which equipment is controlled by the buttons on the optional SpaLink(s). Default settings are spa, spa heat, Aux1, Aux2, Aux3, Aux4, and Aux5. You can now assign a OneTouch macro setting to any button on the SpaLink remote. You may want to write down your SpaLink button assignments so that you can label the buttons on the switch with the label pack provided.
Page 31 Dusk Setup Menu The Dusk Setup menu is used to set a device to automatically turn on at sunset. You can set the duration, a time adjust value if you live between major city selections or in a heavily shaded area, and set specific devices. NOTE Time and Date must be correct, see Set Time. To use the Dusk Setup menu Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight DUSK SETUP and press SELECT. Highlight DUSK CTRL, press SELECT.
Page 32 All Off Time Menu This ALL OFF TIME menu is used to direct the system to turn everything off at a specific time everyday. To use the All Off Time menu Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight ALL OFF TIME and press SELECT. Highlight FEATURE and press SELECT. Use an UP/DOWN arrow key to turn the feature on. Highlight OFF TIME and press SELECT. Use the UP/DOWN arrow keys to select a time all equipment will go off.
Page 33 Set Color Lights Menu NOTE This equipment may not be part of your system. Please check with your installer. The COLOR LIGHTS menu is used to select the color light type (Jandy® or Pentair® SAmTM/SAL®), and to assign the color light to an available auxiliary relay. To set Color Lights Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight COLOR LIGHTS and press SELECT. Use the UP/DOWN arrow keys to highlight the light type to be controlled, then press SELECT.
Page 34 Heat Pump Menu The HEAT PUMP SETUP menu is used to put the heat pump into the heat or chill mode. If the heat mode is selected, then HEAT PUMP will be displayed on the EQUIPMENT ON/OFF menu. If chill mode is selected then CHILLER will be displayed on the EQUIPMENT ON/OFF menu. NOTE In addition to setting heat or chill mode from the Heat Pump Setup menu, the switch on the heat pump must be manually set to heat or chill.
Page 35 Section 8. Glossaries 8.1 Glossary of Safety Delays and Lockouts Lockouts - Any device can be locked out. This will prevent the locked out device from being turned on, both manually and through programming. Pool/Spa Switching Filter Pump Delay - The filter pump turns off while valves rotate between pool and spa to prevent damage to the pool equipment. The valves take 35 seconds to rotate between pool and spa; the filter pump will activate as soon as the valves have finished turning.
Page 36 8.3 Glossary of Controller Messages BATTERY is LOW - This message (located in Diagnostics under the MENU/HELP) indicates that the battery supplying power to the Power Center clock (in case of power outage) is low, and should be replaced. The battery is a standard 9V, and may be replaced by removing the battery door (marked on the Power Center - Power Center is located by the pool equipment).
Page 37 Section 9. OneTouch Menu Flow Chart EQUIPMENT ON/OFF SELECT EQUIPMENT ON ALL OFF OFF MODEL KEYS SPA MODE ONETOUCH ON/OFF ON CLEAN MODE SPA HEAT ADD PROGRAM SET POOL* SET SPA* DISPLAY LIGHT ON OFF SYSTEM LOCK 2 MIN.
Page 38 NOTES
Page 39 Equipment Information Record Date of Installation INSTALLER INFORMATION Initial Pressure Gauge Reading (with clean filter) Pump Model Horsepower Filter Model Serial Number CONTROL PANEL MODEL Serial Number Notes:
LIMITED WARRANTY Thank you for purchasing Jandy® pool and spa products. Jandy Pool Products, Inc. warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions: • AquaLink® RS units installed with Jandy® Surge Protection Kits will be covered for two years. • NeverLube® valves are warranted for the life of pool and/or spa on which they were originally installed.