Installation and Operating Data Installation and Operation Manual Stealth™ Series Pumps Models SHPF and SHPM WARNING H0573800F FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in pool/spa installation. The procedures in this manual must be followed exactly.
Stealth™ Series Pumps Installation and Operation Manual Page 3 Table of Contents 4 Section 5. Service and Maintenance ................. 13 Safety Instructions .......................... Pool Pump Suction Entrapment Prevention Guidelines ..................... Section 2. General Description.......................... 4 5.1 Routine Maintenance ...................... 5.2 Winterizing the Pump ..................... Section 6. Troubleshooting and Repair ............. 13 13 14 2.1 Introduction .............
Page 4 Stealth™ Series Pumps Installation and Operation Manual Section 1. IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS 1.1 Safety Instructions All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
Stealth™ Series Pumps Installation and Operation Manual Page 5 WARNING To minimize the risk of severe injury or death the filter and/or pump should not be subjected to the piping system pressurization test. Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps. Jandy pool equipment is pressure tested at the factory.
Page 6 1.2 Stealth™ Series Pumps Installation and Operation Manual Pool Pump Suction Entrapment Prevention Guidelines WARNING SUCTION HAZARD. Can cause serious injury or death. Do not use this pump for wading pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two (2) functioning suction outlets. WARNING Pump suction is hazardous and can trap and drown or disembowel bathers.
Stealth™ Series Pumps Installation and Operation Manual At least three (3) feet Listed/certified to latest published version of ANSI/ASME A112.19.8 - 2007 Anti-entrapment Cover/Grate or Suction Fitting, screw-fastened to Main Drain Sump No valves between Tee and Main Drains Suction Outlet (Main Drain) Suction Outlet (Main Drain) Valves OK between pump and Tee Figure 1. Listed/certified to latest published version of ANSI/ASME A112.19.
Page 8 Stealth™ Series Pumps Installation and Operation Manual Section 2. General Description 2.1 2. Introduction This manual contains information for the proper installation, operation and maintenance of Jandy Stealth (SHP) Series Pumps. Procedures in this manual must be followed exactly. To obtain additional copies of this manual contact Zodiac Pool Systems, Inc. at 800.822.7933. For address information, see the back cover of this manual. 2.
Stealth™ Series Pumps Installation and Operation Manual - 3" for 3.0 HP* - 4" for 5.0 HP* 4. * HP refers to full-rated pumps 3.1.3.2 Discharge Pipe When the pump is located up to 50 feet from the pool, the recommended minimum pipe size for the discharge side of the pump is: - 2" for .75 to 1.5 HP* - 2½" for 2.0 HP* - 3" for 3.0 HP* - 4" for 5.0 HP* * HP refers to full-rated pumps NOTE All pipe sizes are able to withstand the pressures the pump will deliver, but not necessarily the flow.
Page 10 Stealth™ Series Pumps Installation and Operation Manual CAUTION CAUTION Failure to provide data plate voltage (within 10%) during operation will cause the motor to overheat and void the warranty. The pump must be permanently connected to a dedicated electrical circuit. No other equipment, lights, appliances or outlets may be connected to the pump circuit, with the exception of devices that may be required to operate simultaneously with the pump, such as a chlorinating device or heater. 3.2.
Page 11 Stealth™ Series Pumps Installation and Operation Manual 3.3 Pressure Testing Lid with Locking Ring All Jandy model SHP pumps come with an additional disposable o-ring for pressure testing. This is the blue pressure test o-ring. See Figures 2 and 3. CAUTION Do not open the pump lid before pressure testing, because the blue pressure test o-ring may fall out. If this happens, you will need to replace it. If you have not opened the pump lid, skip to Section 3.3.2, Conduct Pressure Test. 3.3.
Page 12 Stealth™ Series Pumps Installation and Operation Manual Upside Down View of Bottom of Lid Groove where Seal is seated Figure 4. Step where blue pressure test O-ring is seated WARNING Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool professional. Circulation equipment that is not tested properly can fail, which could result in severe injury or property damage. 1. Fill the system with water, using care to eliminate trapped air. 2.
Stealth™ Series Pumps Installation and Operation Manual 5. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid, hand-tighten only. Make sure all valves are open and the unions are tight. 6. Turn on the power to the pump. Then turn on the pump. 7. Once all the air has left the filter, close the pressure release valve. 8. The pump should prime. The time it takes to prime will depend on the elevation and length of pipe used on the suction supply pipe. See Section 3.1.
Page 14 Stealth™ Series Pumps Installation and Operation Manual Section 6. Troubleshooting and Repair Zodiac Pool Systems, Inc. strongly recommends that you call a qualified service technician to perform any repairs on the filter/pump system. To locate an independent service company, check your local yellow pages or visit www.jandy.com and click on "Product Support." 6.1 Troubleshooting Symptom The cleaning/circulating system is not operating correctly.
Page 15 Stealth™ Series Pumps Installation and Operation Manual 6.2 Service Technician Maintenance 2. Turn off any valves to prevent pool water from Reaching the pump. Drain the water from the pump by loosening the unions or removing the drain plugs. 3. Using a 9/16" wrench, loosen the bolts connecting the pump body to the motor backplate. See Figure 5. WARNING This pump must be serviced by a professional service technician, qualified in pool/spa installation.
Page 16 Stealth™ Series Pumps Installation and Operation Manual Diffuser O-Ring Pump Body Diffuser Screws with Washers (2) Self Sealing Left Handed Screw Backplate O-ring Diffuser O-ring Diffuser Diffuser Impeller Mechanical Seal O-ring Location for SHP Only Backplate O-ring Location for PHP/MHP Only Figure 7. Figure 10. Diffuser and Impeller Exploded View Location of the Diffuser O-ring Pump Body 6.
Page 17 Stealth™ Series Pumps Installation and Operation Manual 2. While holding the motor shaft with a ½" wrench, thread the impeller onto the motor shaft. Hand-tighten the impeller until it is secure. Install the impeller center screw into the center of the impeller and tighten, using a No. 3 Phillips screwdriver. Do not overtighten. NOTE The impeller center screw is a left-hand threaded screw. Therefore, turn the screw counter-clockwise to tighten. 3. 4. 5. 6. 7. 8. 9.
Page 18 Stealth™ Series Pumps Installation and Operation Manual 4. Place the backplate o-ring side down and force the ceramic seal out using a screwdriver or drift. 5. Turn the backplate o-ring side up and insert the new ceramic seal side into the backplate. Use great care to press the seal in squarely with your fingers. The ceramic is easily damaged and must be pressed in using only your fingers or soft tools. Do not use any lubricant other than water and soap solution. 6.
Stealth™ Series Pumps Installation and Operation Manual Section 7. Product Specifications and Technical Data 7.1 Replacement Parts List To order or purchase parts for Jandy pumps, contact your nearest Jandy dealer. If they cannot supply you with what you need, contact Zodiac Technical Support at 800.822.7933 or send an e-mail message to techsupport.vista@zmp-zodiac.com. Key No.
Page 20 Key No. 4 4 5 6 7 8 9 10 11 12 12 13 14 15 16 17 18 19 7.2 Stealth™ Series Pumps Installation and Operation Manual Model No.
Page 21 Stealth™ Series Pumps Installation and Operation Manual 7.3 SHPF and SHPM Pump Curves Jandy Stealth Series High Head Pumps Full-Rated (SHPF) and Max-Rated (SHPM) 120 50 110 45 100 Total Dynamic Head (FEET of H2O) SHPF 5.0 80 70 35 30 60 SHPF 3.0/ SHPF 3.0-3PH 50 SHPF 2.0/ SHPM 2.5 Low Speed 40 30 SHPF 2.0/ SHPF 2.0-3PH/ SHPM 2.5 SHPF .50/ SHPM .75 SHPF 1.5/ SHPM 2.0 Low Speed 0 10 20 SHPF .75/ SHPM 1.0 SHPF 1.0/ Low Speed 0 30 40 50 60 20 15 20 10 25 70 80 SHPF 1.
Page 22 7.4 Stealth™ Series Pumps Installation and Operation Manual Physical and Operational Specifications 7.4.1 SHPF Pump Specifications Model No. HP Voltage Amps Pipe Size Carton Weight Overall Length 'A' SHPF .50 .50 208-230/115 4.4-4.5/8.8 2-2½" 30 lbs. 311/8" SHPF .75 .75 208-230/115 6.0-5.6/11.2 2-2½" 43 lbs. 317/8" SHPF 1.0 1.0 208-230/115 7.8-7.4/14.8 2-2½" 45 lbs. 32¼" SHPF 1.5 1.5 208-230 9.6-8.8 2-2½" 50 lbs. 325/8" SHPF 2.0 2.0 208-230 11.0-10.
Stealth™ Series Pumps Installation and Operation Manual Page 23 7.4.3 Pump Dimensions 'A' 113/8" 161/8" 15¼" 103/8" 103/8" 9" 14¾" Bolt Holes, Center to Center Front Edge of Union to Center of Bolt Holes NOTE When installing pump, leave a minimum of two feet (2 ft) of clearance above the pump for removal of strainer basket. 7.5 SHP Replacement Motor Guide SHPF Pumps SHPM Pumps Pump Model A.O Smith / Century Pump Model A.O Smith/ Century SHPF .50 B845 SHPM 1.0 B863SE SHPF .
LIMITED WARRANTY Thank you for purchasing Jandy® pool and spa products. Zodiac Pool Systems, Inc. warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one (1) year from the date of retail purchase, with the following exceptions: • AquaLink® RS units installed with Jandy® Surge Protection Kits will be covered for two (2) years. • Never Lube® valves are warranted for the life of the pool and/or spa on which they were originally installed.