Instructions / Assembly

Page 11
Stealth
Series Pumps Installation and Operation Manual
3. Make sure all necessary isolation valves are closed
to prevent pool water from reaching the pump.
4. Following the markings on the locking ring, turn
the ring counter-clockwise until the ‘START’
markings align with the ports.
5. Carefully remove the lid with locking ring.
3.3.1.2 Replace Blue O-ring
1. Turn the lid with locking ring upside down and
place it on a stable surface.
2. Place the blue o-ring on the step located ¼" from
the bottom of the lid. (See Figure 4.)
3. Make sure that the o-ring is properly seated. It
helps to “place” the o-ring on the step rather than
to “roll” it on. That prevents it from rolling off.
NOTE The blue o-ring sits approximately ¼" away
from the seal. See Figure 4.
Lid and Locking
Ring and Seal
Blue Pressure
Test O-ring
Pump Debris
Trap Basket
(Inside Pump)
Figure 2. Exploded View of Pump
Blue Pressure Test O-ring
Seal
Lid with Locking Ring
Figure 3. Blue Pressure Test O-ring in Lid
Assembly
3.3 Pressure Testing
All Jandy model SHP pumps come with an
additional disposable o-ring for pressure testing. This is
the blue pressure test o-ring. See Figures 2 and 3.
CAUTION
Do not open the pump lid before pressure testing,
because the blue pressure test o-ring may fall out. If
this happens, you will need to replace it.
If you have not opened the pump lid, skip to
Section 3.3.2, Conduct Pressure Test.
3.3.1 Replace Blue Pressure Test O-ring if
Necessary
If you open the pump lid before conducting the
pressure test, the blue o-ring will probably fall out. If
this happens, you will need to install it on the lid again
before conducting pressure testing.
There is a risk of damage to the blue o-ring during
re-installation. If you damage it when trying to re-install
it, you will need to order a new blue pressure test o-ring
(R0479000) before you begin conducting the pressure
test.
These instructions describe the proper procedures
for replacing, using, and disposing of the blue o-ring.
These instructions must be followed exactly.
Read through the instructions completely before
starting the procedure.
3.3.1.1 Remove Pump Lid
1. Make sure that the pump is turned off.
2. Make sure that the switch to the circuit breaker
that powers the pump motor is turned off.
WARNING
Turn off the pump and the main breaker in the pump
electrical circuit before starting the procedure. Failure
to comply may cause a shock hazard, resulting in
severe personal injury or death.
WARNING
Due to the potential risk of re, electric shock, or
injuries to persons, Jandy
Pumps must be installed in
accordance with the National Electrical Code (NEC),
in the USA, or the Canadian Electrical Code (CEC)
in Canada. All applicable local codes must also be
followed.
The NEC may be obtained by contacting the
National Fire Protection Association (NFPA) at