6.2 Service Technician Maintenance
WARNING
This pump must be serviced by a professional
service technician, quali ed in pool/spa installa-
tion. The following procedures must be followed
exactly. Improper in stal la tion and/or op er a tion can
create dangerous electrical hazards, which can
cause high voltages to run through the electrical
system, possibly causing property damage, seri-
ous injury, or death. Improper in stal la tion and/or
op er a tion will void the warranty.
6.2.1 Blocked Impeller
WARNING
While servicing the pump, switch off the circuit
breakers at the power source. Severe personal
injury or death may occur if the pump starts while
your hand is inside the pump.
1. Turn off the pump. Switch off the circuit breaker
to the pump motor.
2. Remove the lid and basket.
3. Look inside the pump for any debris. Remove any
debris found inside.
4. Replace the basket and lid.
5. Switch on the circuit breaker to the pump motor.
6. Turn on the pump, and see if the problem is
solved.
7. If the impeller is still blocked with debris and it
is not possible to remove the debris using steps 2
through 4, the pump will need to be disassembled
in order to access the inlet and outlet of the
impeller.
6.2.2 Impeller Removal
WARNING
While servicing the pump, switch off the circuit
breakers at the power source. Severe personal
injury or death may occur if the pump starts while
your hand is inside the pump.
1. Turn off the pump. Switch off the circuit breaker
to the pump motor. If you are not replacing the
motor, do not disconnect the electrical wiring.
NOTE If you are replacing the motor, Zodiac Pool
Systems, Inc. strongly recommends that a
qualified service technician or electrician
properly disconnect the electrical wiring at the
pump motor.
2. Turn off any valves to prevent pool water from
Reaching the pump. Drain the water from the
pump by loosening the unions or removing the
drain plugs.
3. Using a 9/16" wrench, loosen the bolts connecting
the pump body to the motor backplate. See
Figure 5.
4. Pull the motor and backplate out of the pump
body. Remove the pump body o-ring. The impeller
is connected to the motor shaft.
5. Using a No. 1 Phillips screwdriver, remove the
two (2) screws holding the diffuser. (The diffuser
is the cover over the impeller.) Then remove the
diffuser (See Figure 6). The SHPF 5.0 uses a
different diffuser than other models (See Figure 8).
NOTE At this point you have access to the inlet and
outlet of the impeller to remove any debris.
Figure 5. Remove the Pump Housing
Pump
Body
Motor
Backplate
Bolt (8)
Motor Shaft Cover
Figure 6. Remove the Diffuser
Backplate
Screws
with Washers
(2)
Dif fus er
Motor
Motor
Dif fus er O-ring