Troubleshooting iVIZION™2 Series Banknote Validator Foundation of Intelligent Validation Section 8
P/N 960-000231R_Rev. A © 2022, JAPAN CASH MACHINE CO., LTD.
33
LED Error Codes; ICB
Red Flashes
(12)
Anti-Stringing Error
Fraud detected.
• Check that there is any trace of fraud activity
such stringing.
• Check that the relative Part(s) are properly
assembled and/or Harness are connected.
• Clean and calibrate the relative Sensor(s).
• String Detection Sensor
Red
Flashes
(13)
Reserved - -
Red Flashes
(14)
Damaged PCB
An IC is
malfunctioning
• Replace the relative PCB(s) if necessary as
they may be damaged.
• CPU Board
• MGU Board
• CIS Board
• Transport Encoder Board
• Stack Encoder Board
• Stack Home Position Sensor
Board
Red Flashes
(15)
ROM/RAM Error
A ROM or RAM is
malfunctioning
• Replace the CPU Board if necessary as it
fails to start.
• CPU Board
Table 22 LED Error Codes; ICB
Status LED Error Solution Relative Part/Sensor
Blue Flashes
1 Time
RFID Module Error
Unable to communicate
with RFID
• Check that the relative Part(s) are properly
assembled and/or Harness are connected.
• RFID Module
• CPU Board CN12
• MGU Board CN6
Blue Flashes
2 Times
ICB Function
(Settings) Error
The ICB Function Setting
is incorrect
To enable the ICB Function:
• Enable the ICB Function.
• Reset the Cash Box.
• Replace the relative Part(s) if the solutions
above does not resolve the error.
To disable the ICB Function:
• Disable the ICB Function.
• Set the Cash Box to INHIBIT.
• Replace the relative Part(s) if the solutions
above does not resolve the error.
• RFID Module
• CPU Board CN12
• MGU Board CN6
Blue Flashes
(3)
ICB R/W Error
Unable to communicate
with ICB
• Check that the RFID Transmitter and
Module in the Cash Box perform properly.
• Replace the relative Part(s) if the solutions
above does not resolve the error.
• RFID Module
• CPU Board CN12
• MGU Board CN6
Blue Flashes
(4)
ICB Data Error
Incorrect ICB Data
• Replace the Cash Box with a cleared Cash
Box
• Replace the relative Part(s) if the solutions
above does not resolve the error.
• RFID Module
• CPU Board CN12
• MGU Board CN6
Blue Flashes
(5)
ICB Number Error
The number of the Game
Machine is differrent
• Replace the Cash Box with the one that has
been reset or has the matching machine
number.
• Replace the relative Part(s) if the solutions
above does not resolve the error.
• RFID Module
• CPU Board CN12
• MGU Board CN6
Blue Flashes
(6)
ICB Initialize Error
The Cash Box has not
been reset
• Replace the Cash Box with the one that has
been reset.
• Replace the relative Part(s) if the solutions
above does not resolve the error.
• RFID Module
• CPU Board CN12
• MGU Board CN6
Table 21 LED Error Codes; General (Continued)
Status LED Error Solution Relative Part/Sensor