Manual

3-92
3.7.8 Battery charge mode (Ordinary/Equal) setting
Procedure
1. Press Menu button and turn the dial to “CHARGE METHOD” menu on the LCD.
CHARGE METHOD
2. Press ENT button.
The menu is selected and LCD shows setting of CHARGE METHOD.
CHARGE METHOD
ORDINARY
3. Turn the dial to select ORDINARY or EQUAL.
CHARGE METHOD
EQUAL
ORDINARY: Automatic charge mode where the battery is kept fully-charged. This mode is
normally used.
EQUAL: Equaizing charge mode.
After setting it as EQUAL mode, when charge current decreased, or when charge
time has passed for 2 hours, it changes to ORDINARY mode automatically.
4. Press ENT
button to set it and return to menu selection.
When charge mode changes the EQUAL to the ORDINARY, JSB-196GM may turn off. In
this case turn on the JSB-196GM.
3.7.9 DC operation
Attention for DC operation
1. Single Setting
Either JSB or SES is usable in this setting.
Turn on JSB-196GM : SES is turned off automatically.
(JSB-196GM shows “SES OFF” on LCD.)
Turn off JSB-196GM : SES is turned on automatically after 30-60sec.
2. Dual Setting
Both JSB and SES are simultaneously usable in the setting.
Refer to “Installation manual” about Single/Dual setting.
Note
Note