9.1.5 Environmental condition
Durability and resistance to environmental conditions: protected from the weather (IEC 60945)
(1) Operating temperature : -15°C to +55°C (IEC 60945)
(2) Storage temperature : -25°C to +75°C
(3) Water resistance : IPX2
9.1.6 Supported interface sentences
Indication Sentence format Supported sentence formatters
Input data
Longitude/Latitude
Time of Position
RMC, GGA,GLL
Datum Reference DTM
Speed Over Ground (SOG) RMC, VTG
Course Over Ground (COG) RMC, VTG
Heading HDT
Rate of Turn ROT
IEC61162-1
(NMEA Ver 1.5 -
2.3)
Acknowledge alarm ACK
Request NAVTEX messages NRQ IEC61097-6
Set NAVTEX mask NMK
Output data
IEC61162-1 Set alarm state ALR
New NAVTEX received message NRX
DATA IN
DATA OUT
IEC61097-6
Set NAVTEX mask NMK
9.1.7 Received message log
(1) Stored message : Stores the 200 last received messages
(*1)
. (Each channel)
(2) Saved message : Stores the 50 stored messages
(*1)
. (Each channel)
(*1)
: message ... 500 character long message
Stored messages are erased 70 hours after their reception.
The source of time for handling message ageing is RMC sentence from an external source
(DATA IN).
When the data from the external source is not inputted, it is counted by the internal timer.