User's Manual

JMA-9100 Instruction Manual > A.NQE-3141 Interswitch Unit > A.3 REFERENCE
A11
A
pulse length, the range of the slave display unit may be forcibly changed. In this
case, is shown in the alarm indication (lower right of the
display), and the alarm sounds.
A.3.4 Setting at Installation
Setting of the interswitch circuit (CCL-304*)
The settings of the DIP switches SW11 to SW13 are shown below.
1) SW11 setting (extension mode and master/slave settings)
Master Range CHG
SW 11
SW 13 SW 12
Interswitch circuit PCB
CCL-304*
4 Description
Extension mode setting
ON Extension mode
OFF Normal mode
3 Description
ON Slave
OFF Master
1, 2 Description
ON Unused
OFF Unused
Unused
Master/slave setting
Set the switch to OFF if the
number of connected display
units is four or less.
Set the switch to ON if the
slave ISW PCB is selected in
extension mode.
Set the switch to OFF in
normal state.
1234
ON
OFF