User's Manual

3-93
[4] Time Range
Set the time range for the water-temperature graph.
10min : The time range is set at 10 minutes.
15min : The time range is set at 15 minutes.
30min : The time range is set at 30 minutes.
60min : The time range is set at 60 minutes.
12hour : The time range is set at 12 hours.
[6] Course Bar Setting >
The Course Bar Setting menu will appear.
[1] Course Bar Display
Determine whether to display the bar graph for the course data that has been received of the
display.
One of two digital information areas is used to display data.
When the course-bar graph is displayed, the sizes of the target tracking (TT) / AIS information
areas are exclusively decreased.
Put the cursor on the digital information display Target (menu on page 2-27), and press the
[ENT] key. The course bar display function is switched between on and off.
Off : The course bar graph is not displayed.
Area1 : The course bar graph is displayed in the numeric value data area 1.
Area2 : The course bar graph is displayed in the numeric value data area 2.
[2] AUTO Pilot Course
Determine which field of the APB sentence that has been received is used to display Autopilot
(AP) course.
Course to Steer : The steering angle is displayed.
From ORG : The bearing difference from the original point is displayed.
From CURR POSN : The bearing difference from own ship is displayed.
[3] ROT Scale
Set the maximum scale for the TURN Rate graph.
30-0-30 : The scale is set at ±30 °/min.
60-0-60 : The scale is set at ±60 °/min.
90-0-90 : The scale is set at ±90 °/min.
120-0-120 : The scale is set at ±120 °/min.
150-0-150 : The scale is set at ±150 °/min.
300-0-300 : The scale is set at ±300 °/min.