User's Manual

4-5
To return the EBL starting point to radar station position
Procedures 1 Make EBL1 or EBL2 operable.
2 Press the [EBL] dial to set for the EBL1 / EBL2 starting point
mode switching (upper right of the display /on page 2-19).
The selected EBL starting point will be set as the radar station display position.
[III] Setting EBL Operation Mode
To set the numeric value display mode of EBL (EBL Bearing REF)
Determine whether to display EBL in true bearing mode or relative bearing mode.
(Even if this mode is switched, measured values do not change on the JPL-600MK2.)
Procedures 1 Put the cursor on the EBL1/2 numeric value indication true / relative
switching (upper right of the display /on page 2-19), and press
the [ENT] key.
The selected mode is switched as shown below each time the [ENT] key is pressed.
T R T
T :EBL bearing is displayed in true bearing mode.
R :EBL bearing is displayed in relative bearing mode.
To set a mode for fixing EBL display (EBL Bearing Fix)
(Not used on the JPL-600MK2)
When this function is set to Angle , an EBL is fixed to the preset bearing.
When the function is set to Screen , the EBL is fixed on the radar display.
Procedures 1 Press the [RADAR MENU] key twice.
2 Open the EBL/Cursor Setting menu by performing the following menu
operation.
5. Sub Menu
9. EBL/Cursor Setting
3 Press [1] or [2] key.
To set EBL1, press the [1] key, to set EBL2, press the [2] key
Angle :EBL bearing is fixed to the preset value.
Screen :EBL bearing is fixed on the radar display.
Note:
Course data is necessary for turning on this function.