User's Manual

5-19
Manual Acquisition [ACQ]
Note:
If more targets are acquired manually in the condition that the maximum number of targets are
under tracking, the targets cannot acquired.
Procedures 1 Move the cursor onto the target to be acquired, and press the [ACQ]
key.
The target will be acquired and the initial acquisition symbol will be displayed.
The vector will be displayed within one minute.
Target manually acquired.
The initial acquisition symbol is displayed.
Target that has passed for 1 min.
The acquisition symbol and vector are displayed.
To perform operation only in the manual acquisition mode without automatic
acquisition/activation, turn off the automatic acquisition/activation function.
Use of Automatic and Manual Acquisition Modes
Use the manual acquisition mode while the automatic acquisition mode is on.
Manually acquire the target to which particular attention should be paid, and get the other targets
automatically acquired. If a new target appears exceeding the maximum number of targets, the manually
acquired target is displayed even in the background until it gets out of the display. However, automatically
acquired targets are canceled starting far distance from own ship.