User's Manual

7-1
7.1 SETTINGS AT INSTALLATION
This section describes the electrical adjustment procedures to be performed by service engineers during
system installation.
The bearing adjustment value is saved to non-volatile memory in the scanner. Other settings are saviedto
non-volatile memory in the radar process unit.
CAUTION
Any adjustments must be made by specialized service
personnel.
Incorrect settings may result in unstable operation.
Do not make any adjustments during operation. Failure to
comply may result in adverse effects on the radar function
which may lead to accidents or equipment failure.
7.1.1 How to Open the Serviceman Menu
(Some items are not set on the JPL-600-MK2 for VTS.)
Procedures 1. Press the [RADAR Menu] key for 2
seconds.
The Code Input menu will appear.
2. Press [0] key.
3. Put the cursor on the ENT button,
and press the [ENT] key.
The Serviceman Menu will appear.