User's Manual

JMA-9172-SA Instruction Manual > 3.BASIC OPERATION > 3.9 USE FUNCTION KEY [USER]
3117
3
3.9.4 Overview of saved Function Setting Data
The overview of saved function setting data is as follows:
Procedures
1) Open the User Function Setting menu by performing the menu
operation below.
→ 
→ 
→ 
page 1-[1] Mode
Calls the default value of the mode, and saves it for the function number.
page 1-[6] Save Present State
The currently operating state can be saved for the function number.
Use this function to save the state of good setting that will be frequently used.
page 5-[8] Set Mode Default
Saves the setting of the current function number, as the default setting of the
mode.
page 5-[9] Initialize
Changes the memory contents of the mode, which is used with the current
function number, back to the factory setting.
Factory-set data: : Saved data that general operation cannot change
Default data: : Standard data of each function mode that users can change
Data that can be
called:
: Saved data that can be called by pressing the [USER] key
Main
3. RADAR Menu
1. Process Setting
8. User Function Setting
Coast
Deepsea
Fishnet
Storm
Calm
Rain
Bird
Long
Buoy
User1
User2
Coast
Deepsea
Fishnet
Storm
Calm
Rain
Bird
Long
Buoy
User1
User2
FUNC1
FUNC2
FUNC3
FUNC4
Present
USER
FUNCTION SETTING
Factory-set data
FUNCTION SETTING
Default data
FUNCTION SETTING
Data that can be called Current data
5-[8
1-[1
5-[9
1-[6