Chapter 12 SPECIFICATIONS
165
12-4 GENERAL SPECIFICATIONS
(1) Class of Emission P0N
(2) Display Color Raster Scan
(3)Display capability WVGA (800x480dots) Screen
(4) Screen 7-inch Color LCD with touch sensor (resistance film type)
(5) Range Scale 0.0625, 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48NM
(48 NM: only 2feet type scanner is available)
User can add 1, 2, 4, 8, 16, and 32NM
(32 NM: only 2feet type scanner is available)
(6) Range Resolution Less than 30m
(7) Minimum Detective Range Less than 40m
(8) Range Accuracy Less than 1% of the maximum distance of the range scale
in use or less than 15m whichever is greater.
(9) Bearing Accuracy Less than ±
(10) Bearing Indication RM: Head-up, North-up, Course-up
TM: North-up, Course-up
(11) Ambient Condition
Standards IEC60945 Ed.4.0
Temperature
Scanner Operation: -25 to +55°C / Storage: -25 to +70°C
Other Unit except Scanner Operation: -15 to +55°C / Storage: -15 to +70°C
Relative Humidity +40°C, 93%
Vibration 2 to 13.2 Hz, amplitude±1mm
13.2 to 100 Hz 0.7 G
Velocity of the wind 100kn
Waterproof/dustproof Scanner IP26
Display unit IP55
(12) Power Supply Input DC 10.8-31.2V (DC12-24V-10%+30%)
(13) Power Consumption Approx. 50W (NKE-1066/NKE-2044).
Maximum: 50W (NKE-1066: SP1, NKE-2044: LP2
transmitting)
(14) Pre heat time Approx. within 1min30sec.
(15) Display unit Refer to Display unit Specifications
(16)Inter-unit Cables Using common scanner connecting cable CFQ-9924-10
Standard Length 10m
Maximum cable length 30m