User's Manual

Chapter 12 SPECIFICATIONS
170
12-6-2 OPERATIONAL PANEL
1) Structure Integrated on the display unit
2) Key
PWR/CLR Short push: Power ON ( at the time of Power OFF)
Long push: Power OFF
PWR/CLR Short push: input cancel, back to a up-layer
3) K
nob Controller PUSH : Menu or Icon selection and
execution
, control
EBL/VRM, number input, Enter, etc.
PUSH + rotation: Brilliance control
4) Touch
control Tap: Menu or Icon selection and
execution
, control, etc.
Double tap: Brilliance menu
Icon Double tap: EBL/VRM disappear
Icon Long tap: Entry of short cut Icon
12-6-3 AIS FUNCTION (STANDARD BUILT IN)
1) Display
Number of targets Up to 50 targets (stores up to 500 ship static data)
Target information Displays MMSI, call sign, ship name, COG, SOG, CPA, TCPA, direction,
distance, latitude, longitude, status, etc.
Filters Distance only
Active targets Not available
Dangerous ship targets No CPA/TCPA decision
2) Operation Built-in
12-6-4 TT FUNCTION (STANDARD BUILT IN)
1) Acquisition MANUAL/AUTO (by automatic acquisition/activation zone)
2) Tracking 10 targets (Automatic tracking)
3) Display
Tracking data 1 ship (AIS or TT)
Maximum tracking range 20NM (This varies depending on the range)
Target information Displays items selected from true bearing, distance,
true course, true speed, CPA, TCPA.
Display of Vectors True/Relative
4) Operation Built-in