User's Manual

7.1 SETTINGS AT INSTALLATION
76
7
yyy
yyyy
7.1.3 Bearing Adjustment
Adjust the bearing so that bearing of the target measured with the ship’s compass matches that of the target
echo on the radar display.
Procedure 1 Press AZI MODE to select the relative
bearing presentation [H UP] mode. Set
Image Processing to OFF.
[AZI MODE] Software button located at
the top left corner of the radar display described
in Section 2.3.1 Software button located
at the bottom left corner of the radar display
described in Section 2.3.2.
2 Measure the bearing of an adequate
target (for example, a ship at anchor, a
breakwater or a buoy) relative to own
ship’s heading.
3 Hold down [RADAR MENU] key.
The Code Input Menu will appear.
4 Press [0] key.
5 Move the cursor onto the “ENT” button in the Code Input menu, and
press [ENT] key.
The Adjust Menu will appear.
6 Press [1] key.
Equipment Setup menu opens.
7 Press [1] key.
The Code Input Menu will appear.
8 Using numeric key, enter the value and then press “ENT” button, and
press “EXIT” button to determine the value.
The multi-function control can also be used to enter the value.
Make adjustment by the 0.1°.
9 Repeat Step 5 above, and adjust to display the target measured in Step 2
to the measured bearing.
Exit 1 Press [RADAR MENU] key.
The Main Menu will reappear.