SDS

03/25/2015Revision:
03/25/2015Printed:
Page: 5
Jasco Premium Paint and Epoxy Remover
SAFETY DATA SHEET
03/08/2015Supersedes Revision:
Vapors are heavier than air and will collect in low areas.
Store in a cool place in original container and protect from sunlight. Exposure to high
temperatures or prolonged exposure to sun may cause can to leak or swell. Once
opened, remover should be used within six months or properly disposed of to avoid can
deterioration. Do not store near flames or at elevated temperatures.
Keep container tightly closed when not in use.
Precautions To Be Taken in
Storing:
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
OSHA TWA ACGIH TWACAS # Partial Chemical Name Other Limits
PEL: 25 ppm
STEL: 125 ppm (15 min)
TLV: 50 ppm
75-09-2 Dichloromethane {Methylene chloride;
R-30; Freon 30}
No data.
PEL: 200 ppm TLV: 200 ppm
STEL: 250 ppm
67-56-1 Methanol {Methyl alcohol; Carbinol;
Wood alcohol}
No data.
No data. TLV: 200 mg/m3
64742-47-8 Hydrotreated light distillate (petroleum)
No data.
For use in areas with inadequate ventilation or fresh air, wear a properly maintained and
properly fitted NIOSH approved self-contained breathing apparatus or powered air
supply respirator or loose fitting hood.
For OSHA controlled work places and other regular users - Use only with adequate
ventilation under engineered air control systems designed to prevent exceeding the
appropriate TLV.
A dust mask does not provide protection against vapors.
Respiratory Equipment
(Specify Type):
Chemical goggles or face shields are recommended to safeguard against potential eye
contact, irritation, or injury. Chemical goggles or face shields are recommended when
splashing or spraying of chemical is possible. A faceshield provides more protection to
help reduce chemical contact to the face and eyes.
Eye Protection:
Wear gloves with as much resistance to the chemical ingredients as possible. Laminate
film gloves offer the best protection. Other glove materials, such as nitrile rubber,
neoprene, and PVC will be degraded by methylene chloride, but may provide protection
for some amount of time, based on the type of glove and the conditions of use. Consult
your glove supplier for additional information. Gloves contaminated with product should
be discarded and not reused.
Protective Gloves:
Various application methods can dictate use of additional protective safety equipment,
such as impermeable aprons, etc., to minimize exposure.
Other Protective Clothing:
Use only with adequate ventilation to prevent buildup of vapors. If work area is not well
ventilated, do not use this product. Do not use in areas where vapors can accumulate
and concentrate, such as basements, bathrooms or small enclosed areas.
Whenever possible, use outdoors in an open air area. If using indoors open all windows
and doors and maintain a cross ventilation of moving fresh air across the work area. If
strong odor is noticed or you experience slight dizziness, headache, nausea or
eye-watering -- STOP -- ventilation is inadequate. Leave area immediately and move to
fresh air.
Engineering Controls
(Ventilation etc.):
Licensed to W.M. Barr and Company: MIRS MSDS, (c) A V Systems, Inc.
GHS format