FUNCTION: Used in flat roof of any construction. Large low profile dome provides sufficient free area for quick drainage of rain water and protects
the drain sump and connected piping from the intrusion of debris. Wide clamping surface holds flashing and roofing materials without puncturing.
1 1/8 (29) MIN
LARGE GENERAL PURPOSE ROOF DRAINS
LOW PROFILE DOME
REGULARLY FURNISHED:
Duco Cast Iron Body with Combined
Flashing Clamp and Gravel Stop with
Polyethylene Dome.
OPTIONAL MATERIALS:
All Aluminum -AA (Fig. 1010 only)
▲▲ Aluminum Dome -AD
▲▲ Cast Iron Dome -CID
▲▲ Galvanized Cast Iron Dome -CIDG
Galvanized Cast Iron Body & Collar -G
▲▲ Rough Bronze Dome -RBD
Stainless Steel (Specify Fig. 9780)
VARIATIONS:
Expansion Joint (Specify Fig.1710) (Fig. 1010 only)
Extension (Specify Height) -E
"L" Shaped Underdeck Clamp -CL
L Speedi-Set Service Weight
02(50), 03(75), and 04(100)" sizes only
(Fig. 1010 0nly)
LXH Speedi-Set Extra Heavy
02(50), 03(75), and 04(100)" sizes only
(Fig. 1010 only)
NO-HUB Adaptor (Specify Fig. 2646Y)
(Fig. 1020 only)
Secondary Flashing Clamp -C2
Sump Receiver -R
Underdeck Clamp -C
Vandal Proof Dome -U
T Threaded Outlet
*This Dimension to Internal
Stop of Speedi-Set Gasket.
**NOTE: 08(200) & 10(250) outlet
sizes are regularly furnished with
20(510) dia. flange, see back sheet.
If 16(405) dia. flange is required -16
MUST be specified.
Ex: 1010Y08-16 or 1010Y10-16
Fig. 1010C . . . .CAULK OUTLET
Fig. 1010Y . . . .NO-HUB OUTLET
1010, 1020
1010, 1020
CR
TD
TD
5-24-85 NONE
S1010
U
15 1/4 (390) DIA
5 1/4
(135)
B
C
H
G
J
A
Polyethylene Dome
Combined Flashing
Clamp And Gravel Stop
Underdeck Clamp
(When Specified)
Fig. 1020C 02(50), 03(75) & 04(100)" CAULK OUTLET
Fig. 1020T 02(50), 03(75) & 04(100)" THREADED OUTLET
16 (405) DIA
5 1/4
(135)
B
C
H
G
J
A
1 1/8 (29) MIN
Polyethylene Dome
Combined Flashing
Clamp And Gravel Stop
Underdeck Clamp
(When Specified)
Fig. 1020C 05(125) & 06"(150)
CAULK OUTLET
Fig. 1020T 05(125) & 06"(150)
THREADED OUTLET
5 1/4
(135)
B
Polyethylene Dome
Combined Flashing
Clamp And Gravel
Stop
Underdeck Clamp
(When Specified)
A
E DIA
F MIN
D DIA
C*
recommended deck opening
outlet
size
02(50),03(75),04(100)
05(125),06(150)
**
08(200)-16
, **
10(250)-16
17(430) DIA
17(430) DIA
14(355) DIA
14 3/4 (375) DIA
A SIZE
B
C
02 (50)
6 7/8
(175)
8 5/8
(219)
03 (75)
6 3/8
(162)
8 3/4
(220)
04 (100)
5 7/8
(149)
8 3/4
(220)
05 (125)
5
(125)
8 1/2
(215)
06 (150)
4 1/2
(115)
8 1/2
(215)
(SIDE OUTLET)
FREE AREA
SQ IN
(SQ CM)
D
DIA
E
DIA
F
MIN
G H
J
11
(280)
11
(280)
12 1/2
(320)
1 1/8
(29)
1 1/8
(29)
1 1/8
(29)
4 3/4
(120)
6 1/4
(160)
--
6
(150)
6 7/8
(175)
--
7 3/4
(195)
7 3/4
(195)
--
102.5
(661)
102.5
(661)
102.5(661)
122.5(790)
02(50),03(75),
04(100)
05(125),
06(150)
**08(200)-16,
**10(250)-16
A
SIZE
B (BOTTOM OUTLET)
CAULK, NO-HUB,
& SPEEDI-SET
THREADED
C
5
(125)
5
(125)
6
(150)
3 3/4
(95)
3 3/4
(95)
5
(125)
3 3/4
(95)
--
--
15 1/4
(390)
15 1/4
(390)
16
(405)
SIDE OUTLET
NOTE: The dome height is 8 1/4" (210)
for the 122.5 SQ IN free area dome and
is regularly furnished in Cast Iron and is
not available in polyethylene.
with
suffix-R
less
suffix-R
S 06/01/09 Added Optional Dome free areas JJ CL
T 3-12-13 Rev. Tables, Notes TBW CL
U 8-3-15 Added Flow Rate Note TBW BW
R 06-09-08 Added NOTE RN CL
▲▲ Optional Domes’ free area are as follows:
Dome Mat’l 02-06 & 08-16 Outlets
Aluminum 98 (632)
Cast Iron 80 (516)
Bronze 95 (613)
NOTE: Stated flow rates for roof drains
are based on particular test piping
configurations and dimensions.
Installed roof drain flow rates cannot
be stated unless the attached piping
configuration is known and the
effects of the drainage calculated.
NOTE: Dimensions shown in
parentheses are in millimeters.
JAY R.
SMITH MFG. CO
.
®
MEMBER OF MORRIS GROUP INTERNATIONAL
POST OFFICE BOX 3237
MONTGOMERY, ALABAMA 36109-0237 (USA)
TEL: 334-277-8520 FAX: 334-272-7396
www.jrsmith.com
CUSTOMER
DRIVEN
SMITH
®
MEMBER OF:
ASPE
®
S
A
N
I
T
A
R
Y
E
N
G
I
N
E
E
R
I
N
G
P
r
e
v
e
n
t
i
o
n
R
a
t
h
e
r
T
h
a
n
C
u
r
e
SINCE 1926
P
L
U
M
B
I
N
G
A
N
D
D
R
A
I
N
A
G
E
I
N
S
T
I
T
U
T
E
M
E
M
B
E
R
®
M
E
M
B
E
R
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Summary of content (2 pages)