Spec sheet

c Control
25AV-LS, Two-Way Professional Compact Loudspeaker for Life / Safety Applications
Dimensions:
Safety and Regulatory Information:
The Control 25AV-LS has passed extensive testing and is
in compliance with the following specications and uses:
• ListedUL-1480,categoryUUMW when installed with
a junction box (on-wall or in-wall). Forusewithnon-
DCsupervisedsystems.
General Purpose Use Listed UL-1480,
Category UEAY
Control 25AV-LS is suitable for use outdoors in
wet locations
Control 25AV-LS is suitable for use indoors in
damp locations
Suitable for installation using Class 1, Class 2 or
Class 3 wiring methods in accordance with NFPA 70,
National Electric Code, 2002, Article 640, and with
NFPA 72 for use with non-DC supervised control
panels / ampliers.
Suitable with re alarm circuit wiring methods in
accordance with NFPA 70, National Electric Code,
2002, Article 760, and with NFPA 72 for use with
non-DC supervised control panels / ampliers.
EMC Directive 89/336/EEC and Article 10 (1) of the
directive EN50081-1 and EN50082-1
Tested to IEC 60268-5
EN54-24 certied
Measured audibility for the Control 25AV-LS at 10 feet
(3.1 meters) is:
Tap Sound Pressure Level dB(A)
70V, 7.5W 80 dB
70V, 15W 83 dB
70V, 30W 86 dB
70V, 60W 88 dB
100V, 15W 83 dB
100V, 30W 86 dB
100V, 60W 88 dB
8 ohm 90 dB
236 mm
(9.3 in)
187 mm
(7.4 in)
135 mm
(5.3 in)
12
°
5
°
64 mm
(2.5 in)
159 mm
(6.3 in)
70 mm
(2.8 in)
70 mm
(2.8 in)
7 mm
(.27 in)
51 mm
(2.0 in)
89 mm
(3.5 in)