Instruction Manual
company
a
Skytile
®
Base TP(a) and TP(a) UGR Range
DO NOT COVER
WITH INSULATION
Installation instructions for Skytile
®
Base recessed LED panels
INSTALLATION
ENGLISH
• Read instructions and check that you have all of the tools and accessories required to complete the installation correctly. Isolate power supply
before starting the installation.
Standard non-dimmable/dimmable luminaire installation
1. Remove the ceiling tile or tiles from the location where
you wish to install the LED panel.
2. Wire the LED driver to the mains supply as indicated in
gure 1. If a dimmable variant, connect the dimming
control wires (DALI/1-10V)
as shown in gure 2.
3. Move LED panel into the ceiling aperture and when
positioned halfway connect the driver low voltage output
to the LED panel (luminaire) as shown in gure 1.a.
4. Position the LED panel into place in the grid ceiling.
5. Reconnect mains power supply and test for operation.
Wiring connection
Fig.1.a. Luminaire connection
220-240V 50/60Hz / Class II
16W/400mA/30-40V DC / Class III
16W/400mA / 9-24 V DC / Class III
28W/700mA/30-40V DC / Class III
28W/700mA/ 9-58V DC / Class III
38W/900mA/30-40V DC / Class III
38W/900mA/ 9-56V DC / Class III
Non-dimmable
DALI/1-10V
DALI/1-10V
DALI/1-10V
Non-dimmable
Non-dimmable
Fig. 1. Mains Input Cable
Neutral: Blue
Live: Brown
Plug & Play Connectors
Terminal block must comply to EN 60998-2-1 or EN 60998-2-2
DALI control wires
1-10V control wires
DA +
+
DA -
-
Dimming control input
Figure 2.
V2_Oct_2022_RS
Warnings and cautions
• These products are designed for connection to a mains supply of
220-240V~ 50/60Hz
• This luminaire is suitable for indoor use only
• It may be necessary to upgrade your MCBs to allow for increased
inrush current
• Do not cover with insulation
• Do not carry out insulation tests with the product connected to
the circuit
• To avoid electric shock, serious injury or property damage, isolate
power before installing, removing or servicing the product
• It is recommended that luminaires are installed by a qualied
electrician and the installation complies with the local current
wiring regulations
• Any broken or damaged parts should be replaced as soon as possible
JCC will not accept responsibility for claims arising from any
sub-standard installations
• It is recommended that the ambient room temperature should not
exceed 25°C
Type Wattage Colour Temp Lumens LpcW Beam°
CRi:80-89: Ra : 82
TP(a)UGR 16W 4000K 1700 106 90
TP(a)UGR 28W 4000K 3000 107 90
TP(a)UGR 28W 5000K 3000 107 90
TP(a) 28W 5000K 3300 118 115
TP(a) 28W 4000K 3300 118 115
TP(a)UGR 38W 4000K 4150 109 90
RoHS
Compliant
IP20