User's Manual

RADIOBAND SYSTEM INSTALLATION MANUAL V2.2 / 28
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
5. JCM CONTROL PANEL DIAGRAM FOR CONNECTION TO
THE RADIOBAND SYSTEM
SINGLE-PHASE PANELS
JCM Control
panels
Applications Description Compatibility with
Radioband system
START-EU
Roller for
residential and
commercial
use
Semi-automatic
operations. 433 or
868 MHz radio card
connection. Start
button and safety
edge connection.
RADIOBAND/R with external
power supply
RESIDENT+DCS
Roller for
residential use
Semi-automatic and
automatic operations.
Built-in 433 MHz
receiver. Start/stop
button connection,
limit switches and
security contact on
close. Possible to
connect the TBAND
card. 24Vac outlet
Garage light contact
RADIOBAND/R
ROLLER-
MOTION
Roller for
residential and
commercial
use
“Dead-man”
operations (using GO-
BUTTON or GO-
SWITCH), semi-
automatic. Built-in
868 MHz receiver.
Start button
and safety edge
connection.
RADIOBAND/R with external
power supply
BASIC-EU
Sliding for
residential and
community use
Semi-automatic and
automatic operations.
433 or 868 MHz
radio card connector.
Start, pedestrian and
stop button
connection. Limit
switch, safety edge
and security contact
connection. Garage
light contact 12Vdc
outlet
RADIOBAND/R
MAIN-1T-EU
Swing, folding
and sliding for
residential and
community use
Semi-automatic and
automatic operations.
433 or 868 MHz
radio card connector.
Start and stop button
connection. Limit
switch,
safety edge and
security contact
connection. Traffic
light or signal card
connector.
Garage light contact
24Vac outlet Electro-
lock connection
.
RADIOBAND/R
MAIN-2T-EU Same as
MAIN-1T-EU
Same as MAIN-1T-EU
for 2 motors
RADIOBAND/R