User's Manual

RADIOBAND SYSTEM INSTALLATION MANUAL V2.3 beta version / 16
JCM TECHNOLOGIES S.A. ALL RIGHTS RESERVED
INSTALLATION AND CONNECTIONS
Connection to a control panel using a connector for safety devices.
LIGHT INDICATORS
RADIOBAND/R
U-RC-RCS
In operation In programming
Relay 1 LED Normally off.
Indicates the status of the relay output.
If R1 is not connected, on.
On. Indicates the channel to be
programmed.
Relay 2 LED Normally off.
Indicates the status of the relay output.
If R2 is not connected, on.
On. Indicates the channel to be
programmed.
OPERATION
The receiver checks that all the programmed bands are working properly. If a band
is activated or if there is an error in its operation, the receiver activates the output
relay.
MANUAL PROGRAMMING
RADIOBAND/RC-RCS makes it possible to store 6 RADIOBAND/TAs and/or
RADIOBAND/TBXs (3 on Relay 1 and 3 on Relay 2).
Press the receiver programming PROG button for 1s; a sound signal will be heard.
The receiver will enter safety band closing programming mode (BSC). If the
programming button is kept pressed, the receiver will enter safety band opening
programming mode (BSO), moving cyclically from one really to another. Once the
programming relay has been chosen for the transmitter you want to start using,
send the programming code by pressing the transmitter. Every time a transmitter is
programmed, the receiver will emit a sound signal for 0.5s. If 10 seconds pass
without programming, the receiver will go out of programming mode, emitting two
1s sound signals. If, when programming a transmitter, the receiver's memory is full,
it will emit 7 sound signals lasting 0.5s and come out of programming.
Note: For a right operation of the system, the transmitter has to be programmed
in one receiver only.
RADIOBAND/TA, RADIOBAND/TBX replacement: In case you need to replace a
RADIOBAND/TA or a RADIOBAND/TBX, it is necessary to reset the system (see
TOTAL RESET on next page) and reprogram all RADIOBAND/TA and/or
RADIOBAND/TBX used in the installation.
SYSTEM CHECK
This function has to be used to check the operation and range of all the devices
once the installation has been carried out.
Press the receiver’s CHECK button for at least one second to enter check mode.
The indicator light will come on and four beeps will be heard.
Perform a complete door opening and closing manoeuvre. During the system
check a beep will be heard every 1,5 seconds.
CORRECT OPERATION OF THE SYSTEM