3.3 Manual Gain Adjustment ~ UL / DL
In order to meet and maintain safe environmental conditions for seamless
network integration, this repeater is equipped with an LCD interface that
allows you to manually control the Uplink / Downlink gain individually. The UL
/ DL attenuator control range is from 0dB to -31dB by 1dB increments.
When your repeater is switched on, the LCD screen will display the current
UL and DL gain values and output power setting in a scrolling sequence.
Click the ENTER button to access the menu to add or remove attenuation.
Click the UP or DOWN navigation button to access the desired band you
would like to attenuate. (UPLINK or DOWNLINK)
3.3 Manual Gain Adjustment ~ UL / DL – Con’t.
Click the ENTER button again after you have selected the desired band you
would like to attenuate. This will then bring your prompt to the current
attenuation value. (Default is 0dB) You can then use either the UP or
DOWN navigation buttons to add the desired amount of attenuation.
The following example shows a value of 2dB has been selected.
Please note: For the selected value to take effect, you must press the
ENTER button after, or it will not register. You will then get a confirmation
response when the change was successful.
Down Navigation Button
Enter / Select Button
Return Button
The default of UL/DL gain
attenuator is at 0dB. (Full Power)
Up Navigation Button
A
ctive Power Status Scrolling
Down Navigation Button
Down Navigation Button
Up Navigation Button
11