Installation Guide

INSTALLATION INSTRUCTIONS
for Swinging French and Patio Doors (JII105)
3
t7FSJGZUIFXJEUI
and height of the
door are each 1/2"-
3/4" smaller than
the rough opening
width/height,
respectively. Mulled
units should be 3/4"
smaller.
t7FSJGZUIFSPVHI
opening is square.
The (A) and (B)
measurements
should be the same.
Maximum allowable
deviation from
square is 1/4".
2
INSPECT ROUGH OPENING
A
B
D
C
E
Verify Square, Level, & Plumb
t7FSJGZUIFSPVHIPQFOJOHJTMFWFMBOEQMVNC$BOE%5IF
maximum allowable deviation is 1/8".
t5IFSPVHIPQFOJOHTJMMNVTUOPUCFDSPXOFEPSTBHHFE%
t5IFFYUFSJPSGBDFPGUIFSPVHIPQFOJOHNVTUCFJOBTJOHMFQMBOF&
with less than 1/8" twist from corner to corner.
t.JOJNVNEPVCMFTUVETTIPVMECFVTFEBUBMMXPPEGSBNFESPVHI
openings.
t5IFIFBEFSNVTUCFTVQQPSUFECZUSJNNFSTUVET
REMOVE PACKAGING
Remove shipping materials such as corner covers, shipping blocks
or pads.
Note! Be sure to remove the shipping clips from the door before
beginning the installation.
INSPECT PATIO DOOR
t$PTNFUJDEBNBHF
t1SPEVDUTRVBSFOFTTEJBHPOBMNFBTVSFNFOUTNVTUCFXJUIJO
1/4" difference)
1
3&.07&1"$,"(*/(*/41&$5%003
t$PSSFDUQSPEVDUTJ[FDPMPSHSJEQBUUFSOIBOEJOHHMB[JOHFOFSHZ
efciency requirements, etc.)
t4QMJUTDSBDLTIPMFTNJTTJOHTFDUJPOTPSPUIFSEBNBHFUPUIFOBJMJOH
n longer than 6" and/or within 1/2" of door frame
t"ESJQDBQUIBUFYUFOETQBTUUIFFOEPGUIFGSBNFJT
recommended for all products; required for side-by-side mulled units.
If any of the above conditions represent a concern, or if you expect
environmental conditions to exceed the patio door's performance
rating, do not install the patio door. Contact your dealer or distributor
for recommendations.
MATERIALS
tYEFDLESZXBMMTDSFXT
t/PODPNQSFTTJCMFPSXBUFSEFHSBEBCMFTIJNT
t4FBMBOUQPMZVSFUIBOFJGQBJOUFETJMJDPOFJGMFGUFYQPTFEBOE
backer rod
t$MPTFEDFMMQPMZVSFUIBOFMPXFYQBOTJPOGPBN%PX(SFBU4UVGG
Window and Door or equivalent)
t1MBTUJDESBJOTDSFFOXJUIDSJTTDSPTTPSXPWFOQBUUFSOTPMEJOXJEUIT
to protect rain gutters) for step-down landings
t4IFFUNFUBMýBTIJOHPSCFOEBCMFWJOZMTIFFUJOHGPSTJMMQBOXJEF
for 2" x 4" wall)
tTUBQMFTGPSTUFQEPXOMBOEJOHT
For installations into a Buck:
Liquid applied ashing (Protecto Wrap LWM 200 or equivalent)
NEEDED MATERIALS & TOOLS
For installations into a stud-framed wall:
t+&-%8&/XJEFTFMGBEIFTJWFýBTIJOHQBSUPSFRVJWBMFOU
JGSFRVJSFECZMPDBMDPEF
t1SPUFDUP8SBQ4BGTFBM4ZTUFNTTQSBZBEIFTJWFQSJNFSPSBT
recommended by the self-adhesive ashing manufacturer)
Note! Follow all material manufacturers’ instructions for proper use
and compatibility.
TOOLS
t$VUUJOHTIFBSTTJMMQBO
t5BQFNFBTVSF
t6UJMJUZLOJGF
t-FWFMGUNJOJNVN
recommended)
t+SPMMFS
t$BVMLJOHHVO
t%SJMMXJUICJUT
t$POTUSVDUJPOTUBQMFS
t4DSFXESJWFS