For Patio Doors:
Pre-drill and install
fourmore#8x3"
screws through the
thick part of the jamb
where shown in a
similar manner to those
installed previously.
Seat all screws fully.
VinylFrenchandPatioDoors:
Note! Use the six screws that come in the hardware pack to install the
door. The hardware pack also contains six screw caps and a #25 torx bit
to install the screws.
1.Verifythedoorislevel,squareandplumb.Checkforevenmargins
around all panels and the frame and that the lockset holes (if
applicable) align properly. If not, adjust shims. Once the screws are
captured in the jamb jacks, they cannot be removed and reinstalled.
Rough
opening
Door
frame
Jamb
jack
7
INSTALL DOOR - CONTINUED
SECURE THE DOOR
Note! Vinyl door instructions later in this section. All others begin here.
Double door units are shown, however, the fastening instructions also
apply to triple, quad and sidelight French and patio door units.
For French Doors:
Remove a screw from
each hinge next to the
weatherstrip and replace
with one of the provided
#8x3"screws,seating
all screws fully.
ADJUST SILL CAP (IF NECESSARY)
Verifythesweep
properly contacts
the threshold with
1/8" overlap as
shown. Door units
are manufactured
so that, if installed
level and square, the
sweep will contact the
threshold properly,
making adjustments
to the sill cap
unnecessary. However,
if adjustments are
needed, use a at
head screwdriver
to remove screw
covers and turn screw
clockwise to adjust
the sill cap up. Sills are
shipped with sill cap
adjusted all the way
down.
2. Use the jamb jack
screws and TORX
bit (provided) to
initially secure
the frame to the
opening at locations
1 & 2. Turn jamb
jackscrews#1&
#2untiltheyclick
twice. Do the same
for#3.
3. Check the inside
ofjambonthe#1
side for plumb and
adjust by turning
jamb jack screws
clockwise to move
toward the jamb, or
counter clockwise
to move away from
the jamb. Check
unit for plumb,
square and level.
4.Turn#4jambjack
screw until it clicks
twice. Adjust jamb
jack screws on the
#4sidetoplumb
jamb. Again, check
unit for level, plumb
and square.
5.Tightenjambjackscrews#5and#6beingcarefulnottobowtheside
jambs.
6. Check unit for plumb, square and level and adjust as necessary.
3
1
5
4
2
6
Door panel
Threshold
Threshold
Door panel
Sweep