Installation Guide

INSTALLATION INSTRUCTIONS
for Vinyl Windows without Nailing Fin (JII011)
2
MASONRY/BLOCK WALL CONSTRUCTION
This installation
assumes that a building
professional has already
properly fastened and
sealed a framework of
studs (often called a
buck) to the concrete/
masonry wall. If using
a precast sill, the buck
will be installed only on
the head and jambs.
STUD-FRAMED
ROUGH OPENINGS - CONTINUED
SHEATHED WALL CONSTRUCTION
The window will be
mounted inside of the
rough opening.
Buck
Sheathing
Trimmer studs
King
stud
Sill
Header
SAFETY & HANDLING
SAFETY
Read and fully understand ALL manufacturers’ instructions before •
beginning.
Do not work alone. Two or more people are required. Use safe lifting •
techniques.
Use caution when handling glass. Broken or cracked glass can cause •
serious injury.
Wear protective gear (e.g. safety glasses, gloves, ear protection, etc.).•
Operate hand/power tools safely and follow manufacturer’s operating •
instructions.
Use caution when working at elevated heights.•
MATERIALS AND WINDOW HANDLING
Make sure operable windows are locked prior to installation.•
Heed material manufacturers’ handling and application instructions.•
Protect adhesive surfaces from dirt, moisture, direct sunlight and •
folding over onto themselves.
Handle in vertical position;do not carry at or drag on oor.•
Do not put stress on joints, corners or frames.•
Store window in dry, well-ventilated area in vertical, leaning position •
to allow air circulation; do not stack horizontally.
Protect from exposure to direct sunlight during storage.•
Install only into vertical walls and when conditions and sheathing are •
dry.
IF INJURY OCCURS, IMMEDIATELY SEEK MEDICAL ATTENTION!
NEEDED MATERIALS
Note! Follow all material manufacturers' instructions for proper use
and compatibility.
#10 x 2 1/2" corrosion-resistant pan head screws. Screws must •
penetrate at least 1" into framing (or as required by local code)
3/16" x 2 1/2" self-tapping concrete screws for masonry applications •
(or as required by local code)
Sealant (Protecto Wrap Protecto Sealant 25XL or equivalent)•
Backer rod•
Non-Compressible or water degradable shims•
Polyurethane low expansion foam (Dow Great Stuff•
TM
Window and
Door or equivalent)
Additional Materials Needed if Installing into an Existing Window
Frame
Solid wood (cedar or redwood recommended) or exterior grade
plywood for continuous support.
If installing into an aluminum window, dimensions should be 1/2" •
shorter than the length of the sill track and 1/4" taller than the depth
of the track.
If installing into a wood window, dimensions should be 1/4" thick, •
length of the existing frame sill minus 1" and the width of the new
vinyl window side jamb minus 1/4".
Additional Materials Needed if Installing into a Masonry Wall
Liquid applied ashing (Protecto Wrap LWM 200 or equivalent)
Additional Materials Needed if Installing into a Stud Framed Wall
JELD-WEN drain mat material or equivalent.
TOOLS
Tape measure•
Utility knife•
Level (4' minimum recommended)•
J-roller•
Screwdriver•
Hacksaw•
NEEDED MATERIALS & TOOLS
Putty knife•
Caulking gun•
Drill with bits•
Hammer•