COMPLETE INSTALLATION
7
INSTALL DOOR - CONTINUED
6
FIRE DOOR HINGES
Do not remove or paint over any re labels. Please see our separate 
document for additional requirements for installing re-rated doors at 
www.jeld-wen.com/resources. Automatically closing hinges are required 
on re doors and when allowed to close by themselves from 18", should 
close and latch securely. If it does not, adjust the spring as follows:
1. With the door 
closed, insert the 
provided hex wrench 
so that it can be 
rotated clockwise. 
Hold in place and 
remove tension pin 
with a small punch 
ormagnet.
2. Rotate hex wrench 
clockwise 1/4 turn 
and re-insert tension 
pin loosely into 
tensionhole.
3. Remove hex wrench and try closing force.
4. Repeat steps until closing force is adequate but do not rotate past 3 
holes on 180
o
 openings or 4 holes on 90
o
 openings.
1. If installing a re door, verify the correct seal (weatherstrip) is 
installed in the frame and conforms to local codes.
2. Fill any nail/screw holes and sand smooth.
3. Finish all six sides of the door slab as well as the frame.
4. Install exterior wall surface within seven days of installation.
5. Install lockset hardware per supplied instructions.
FINISH INSTALLATION - CONTINUED
9.  Create a continuous air seal on the interior between the rough opening 
and the door frame with low expansion foam. 
10. Ensure sealant on back dam of the sill pan fully seals to the inside 
face of the sill. Apply more sealant as necessary.
11. On the exterior of step-down landings, install support trim 
underneath the sill where it extends past the landing. Position trim 
snugly against the bottom of the sill toe/nose.
6. Remove protective lm (if applicable) on glass after all construction is 
complete or within one year.
7. Protect recently installed units from damage from plaster, paint, etc. 
by covering the unit with plastic.
8. Install any interior trim as desired.
9. Sealant joints will need to be inspected at least once a year and 
repaired as necessary.
Tension 
pin
Tension 
hole
Clockwise