Instructions / Assembly

10
COMPLETE INSTALLATION
7
MAKE FINAL ADJUSTMENTS - IF NECESSARY
1. Doors are adjusted at the factory, but may need additional adjusting
after assembly at the job site. Slide doors into the closed position
and push the ush bolt handles down to secure. Check for an
approximate 3/16" gap between the panels and the head track
and an approximate 3/8" gap between the panels and the sill track
and proper lock
function.
2. Top and bottom
pivots adjust
horizontally
using a #3 Phillips
head screwdriver.
Clockwise
rotations will
move panel away
from the jamb;
counterclockwise
moves the panel
toward the jamb.
Close panel and
adjust until equal
spacing exists
between the panels
and jambs. Check
to ensure the lock
functions properly.
If the panels are too
far apart for the
lock to function,
adjust both ends
equally toward the
center until the lock
functions normally.
3. Bottom pivot blocks
and carrier sets
adjust vertically.
Insert a at head
screwdriver into
the slot to release
the spring and turn the collar with an 14 mm open ended wrench.
One rotation will provide approximately 1/16" adjustment. Right will
raise and left will lower the panel. Adjust as necessary to achieve a
consistent reveal across the opening.
4. If the conguration has the passage door meeting with a strike door,
make sure the doors are aligned along the full height of the door
when closed. If the doors are not aligned, the hinges may have to be
adjusted vertically.
5. Open and close the door system to check for smooth operation.
Shown
from
side
FINISH INSTALLATION
1. If the door unit has a strike jamb against a rough opening jamb,
drive #10 x 2-1/2" screws through the screw holes in the strike plate.
Replace existing screws if necessary. This will secure the door frame to
the structure.
2. Some clad products are shipped with separate astragal covers. If
these are not already installed, wipe the panel area with denatured
alcohol, let dry,
remove the backing
tape and adhere
into place.
3. Press the sill track
seal into place in
the exterior groove
as shown.
4. On the interior side
jambs and head,
create a continuous
air seal between
the rough opening
and the door frame
with backer rod
and sealant or low
expansion foam.
5. On the exterior side
jambs and head,
seal between the
rough opening and
the door frame
with backer rod and
sealant. Allow the foam to fully cure and cut ush with a sharp knife.
Make sure the foam cuts cleanly and doesn’t tear.
6. Install drip cap if required or desired. Fold the building wrap
(previously taped up) down over the drip cap and seal the cut ends
with self-adhered ashing or building wrap tape.
AFTER INSTALLATION
1. Install exterior wall (cladding) surface per manufactures’ guidelines.
2. Leave an expansion/contraction gap of approximately 3/8" between
window frame and nal exterior wall surface (siding, stucco, etc.). For
a nished look and additional protection, seal this gap on the sides
with backer rod and sealant. If sealant is applied above the drip cap
ensure the sealant bead is discontinuous to allow for drainage.
3. Protect recently installed units from damage from plaster, paint, etc.
by covering the unit with plastic.
4. Protect the sill with the protective sill cover until all construction
activities are complete. Resize the cover to t between opened panels
as necessary.
5. Remove labels or other materials adhered to glass within 30 days
after installation.
©2014 JELD-WEN, inc.; This publication and its contents are owned by JELD-WEN, inc. and are protected under the U.S. Copyright Act and other intellectual
property laws. All trademarks, service marks, logos and the like (whether registered or unregistered) are owned or controlled by JELD-WEN, inc. or others.
Unauthorized use or duplication of JELD-WEN intellectual property is prohibited.
JELD-WEN reserves the right to change product specications without notice. Please check our website, jeld-wen.com, for current information.
(12/14)
Horizontal
adjustment
screw
Horizontal
adjustment
screw
Panel
Panel
Head
Sill
Release
spring
Vertical
adjustment
nut
Active panel
Passive
panel (with
astragal
attached)
Cover
Cover
Sill track
seal
Please visit jeld-wen.com for warranty and care and maintenance information.
Thank you for choosing
ASSEMBLY AND INSTALLATION INSTRUCTIONS
for W-4500 Folding Door Systems (JII041)