OPTIONAL HARDWARE INSTALLATION CONTINUED
13
D-Handle Installation
NOTE: The location of the D-handle is on the exterior and the nal
positioning is at the discretion of the end user. Do not install the D-handle
in a location that impedes the operation of the panel hinges. The
installation steps below provide a suggested location.
1. Align the D-handle with the exterior edge of the panel above the
centerhinge.
2. Mark the location of the D-handle screws and pre-drill using a 5/32"
drillbit.
3. Attach the D-handle with the # 10 x 1 1/2" at head screws.
4. Check for operation.
5. Pre-drill the location of the
screws in the strike plate
using a 1/8" drillbit.
6. Install the strike plate
with the #8 x 1 1/4" at
headscrews.
7. Close the door and check
for operation. Make
adjustments as necessary.
NOTE: The ball catch is adjustable. Rotate the ball catch housing to the
left to raise the ball and to the right to lower the ball.
Ball catch closed Ball catch adjusted
D-Handle
Weatherstrip
Weatherstrip
Head jamb